KEITHLEY 4200A-SCS Parameter Analyzer Clarius Plus

Litlhaloso
- Lebitso la Sehlahiswa: Clarius+
- Mofuta: 1.14
- Moetsi: Keithley Instruments
- Aterese: 28775 Aurora Road, Cleveland, Ohio 44139
- Ikopanye le: 1-800-833-9200
- Websebaka: tek.com/keithley
Lintlha tsa bohlokoa
Clarius+ software application suite is the software for the Model 4200A-SCS Parametric Analyzer. Clarius+ software requires Microsoft® Windows® 10 to be installed on your Model 4200A-SCS Parametric Analyzer.
Nalane ea ntlafatso
Tokomane ena e nchafatsoa nako le nako le ho tsamaisoa ka lingoliloeng le lipakana tsa lits'ebeletso ho fana ka tlhaiso-leseling e morao-rao. Nalane ena ea ntlafatso e kenyelelitsoe ka tlase.
| Letsatsi | Mofuta oa software | Nomoro ea litokomane | Phetolelo |
| 4/2025 | v1.14 | 077132619 | 19 |
| 5/2024 | v1.13 | 077132618 | 18 |
| 3/2023 | v1.12 | 077132617 | 17 |
| 6/2022 | V1.11 | 077132616 | 16 |
| 3/2022 | V1.10.1 | 077132615 | 15 |
| 10/2021 | V1.10 | 077132614 | 14 |
| 3/2021 | V1.9.1 | 077132613 | 13 |
| 12/2020 | V1.9 | 077132612 | 12 |
| 6/10/2020 | V1.8.1 | 077132611 | 11 |
| 4/23/2020 | V1.8 | 077132610 | 10 |
| 10/14/2019 | V1.7 | 077132609 | 09 |
| 5/3/2019 | V1.6.1 | 077132608 | 08 |
| 2/28/2019 | V1.6 | 077132607 | 07 |
| 6/8/2018 | V1.5 | 077132606 | 06 |
| 2/23/2018 | V1.4.1 | 077132605 | 05 |
| 11/30/2017 | V1.4 | 077132604 | 04 |
| 5/8/2017 | V1.3 | 077132603 | 03 |
| 3/24/2017 | V1.2 | 077132602 | 02 |
| 10/31/2016 | V1.1 | 077132601 | 01 |
| 9/1/2016 | V1.0 | 077132600 | 00 |
Lintlha tse ncha le lintlafatso
Likarolo tse ncha tse ncha tokollong ena li kenyelletsa:
- Data compression: Set up rules to highlight the display of interesting data while limiting the display of other data.
- Support for using the quasistatic technique for capacitance-voltagLitekanyo tsa e (CV): Laeborari ea mosebelisi, lintlha tsa kopo, projeke le tlhahlobo li kentsoe.
- Support for using the JEDEC JEP183A standard for measuring threshold voltage ho silicon carbide MOSFETs: Laeborari ea basebelisi le liteko li ile tsa eketsoa.
Khatello ea data (CLS-1218)
Karolo ea khatello ea data ea Clarius e fokotsa lintlha tse sa thahaselleng. E u lumella ho bokella lintlha tse sa tsitsang ho tsoa libakeng tse thahasellisang ha u ntse u hatella lintlha tse tsoang libakeng tse ling tsa ho fumana lintlha. Bakeng sa mohlalaample, in a breakdown test, you may want to store uncompressed data points near a breakdown transition, but compress other data. In addition to simplifying the display of data, data compression allows you to execute long-running tests without exceeding the maximum number of points allowed in Clarius. For detailed information on Data Compression, refer to the “Data Compression” section of the Learning Center and the Model 4200A-SCS Clarius User’s Manual. Also see the new application note Long-Term Data Collection and Breakdown Testing Using Data Compression in the Keithley 4200A-SCS Parameter Analyzer.
Quasistatic technique for capacitance voltaglitekanyo tsa e (CV) (CLS-1632)
Liteko tse etsang matla a hona joale a quasistatic capacitance voltagMokhoa oa e (Force-I QSCV) joale o kenyelelitsoe le software ea Clarius. SMU e le 'ngoe e nang le preamplifier is required to run the Force-I QSCV tests. A new application note, Forced Current Quasistatic CV Method for SiC Devices with the 4200A-SCS Parameter Analyzer, describes the Force-I QSCV technique, explains how to use the tests in the Clarius software, compares this technique to other methods, and derives calculations for internal charges on a SiC MOSFET from the forward and reverse C-V sweeps. The new project is named SiC MOS Device Force-I Quasistatic C-V Project (sic-mos-device-force-i-qscv) and includes the tests SiC MOScap Force-I Quasistatic C-V (sic-moscap-force-i-qscv) and SiC MOSFET Force-I Quasistatic C-V (sic-mosfet-force-i-qscv).
JEDEC JEP183A tekanyetso ea ho lekanya moeli oa voltage ho silicon carbide MOSFETs (CLS-1330)
Laeborari e ncha ea mosebelisi ea wbg_ulib e fana ka li-module tsa mosebelisi tse sebelisang maemo a JEDEC JEP183A bakeng sa ho metha threshold vol.tage (VTH) on silicon carbide MOSFETs. The SMU_vgsweepvdfixed user module uses a user-defined Target Current (IdTarget) to find VTH from an ID-VG curve while sweeping VG and biasing VD. The SMU_vgvdsweep user modules uses IdTarget to find VTH from an ID-VG curve while sweeping both VG and biasing VD (VG = VD).
Litokomane lia fetoha
Litokomane tse latelang li ntlafalitsoe ho bontša liphetoho bakeng sa tokollo ena:
- Model 4200A-SCS Clarius User’s Manual (4200A-914-01F)
- Model 4200A-CVIV Multi-Switch User’s Manual (4200A-CVIV-900-01F)
- Model 4200A-SCS Prober and External Instrument Control (4200A-913-01C)
- Model 4200A-SCS Setup and Maintenance User’s Manual (4200A-908-01F)
- Model 4200A-SCS KXCI Remote Control Programming (4200A-KXCI-907-01E)
Likarolo tse ling le liapdeite
| Nomoro ea tlhahiso | CLS-123 / AR-60565, CAS-366256-L7T2N1 |
| Subsystem | Clarius |
| Ntlafatso | You can now choose to preserve the selection of runs in the Run History while the test is running. To set this option, select My Settings > Run Settings dialog, then select “Keep selected runs while running the test.” |
| Nomoro ea tlhahiso | CLS-256 / AR-66864 |
| Subsystem | Clarius |
| Ntlafatso | Clarius Messages pane e ka atolosoa ho hlahisa melaetsa e meng. |
| Nomoro ea tlhahiso | CLS-282 / AR-63405 |
| Subsystem | Clarius |
| Ntlafatso | Hona joale o ka eketsa lintlha tsa morero. O ka fihlella Lintlha tsa Morero ho tloha ho Configure ha morero o khethoa sefateng sa morero le ho tsoa ho Select Projects dialog. |
| Nomoro ea tlhahiso | EA-787 |
| Subsystem | Clarius – Data Export |
| Ntlafatso | The Clarius Data Export tool was updated to support the export of subsite data. In addition, the “Use Clarius data file ho reha lebitso" kgetho e ile ea eketsoa ho lumella ts'ebeliso ea data file mabitso joalo ka ha a entsoe ka hare ho Clarius ho fapana le mabitso a boletsoeng ke basebelisi. |
| Nomoro ea tlhahiso | CLS-1030 / CAS-287410-Z4R7C3 |
| Subsystem | Clarius |
| Ntlafatso | Bolelele ba rekoto ea Clarius Messages bo ile ba eketseha ho kenyelletsa melaetsa e fihlang ho 6000. |
| Nomoro ea tlhahiso | EA-1032 |
| Subsystem | Clarius – Project Tree |
| Ntlafatso | The Project Tree Item Management item was added to Clarius Configure pane when a project is selected. It allows you delete multiple devices and tests in project. |
| Nomoro ea tlhahiso | EA-1113 |
| Subsystem | Clarius – Subsite |
| Ntlafatso | The “Target Values ABS Change” option was added to Clarius subsite stressing. It can be used instead of the “Target % Change” option. |
| Nomoro ea tlhahiso | CLS-1243 / CAS-255291-D9J4H0 |
| Subsystem | Clarius – Subsite |
| Ntlafatso | A dialog was added for the input of list items in subsite stress configuration. It supports flexible functionality to add list items, including the ability to paste data from Microsoft™ Excel™. |
| Nomoro ea tlhahiso | CLS-1486 / CAS-345375-P9Z2T4 |
| Subsystem | Clarius - Lilaebrari tsa Basebelisi |
| Ntlafatso | User modules supporting 4-channel, 6-channel, 8-channel, and multi-channel PMU SegArb were added to PMU_examples_ulib user library. Test names are pmu-segarb-complete-4ch, pmu-segarb-complete-6ch, pmu-segarb-complete-8ch, and pmu-segarb-complete- multi-ch. |
| Nomoro ea tlhahiso | EA-1671 |
| Subsystem | Clarius – Prober Drivers |
| Ntlafatso | Micromanipulator P200L (NP7) Prober Driver support was added to Clarius. |
| Nomoro ea tlhahiso | EA-1692 |
| Subsystem | Clarius – Data Export |
| Ntlafatso | If a path is selected in the Data Export dialog, the path is retained when Clarius is relaunched. |
| Nomoro ea tlhahiso | CLS-1826 / CAS-389128-W6K4Z0 |
| Subsystem | Clarius – Subsite |
| Ntlafatso | Maximum number of cycles/stresses for Clarius Subsite was increased from 128 to 4096. |
Litharollo tsa mathata
| Nomoro ea tlhahiso | EA-1069 |
| Subsystem | UTM UI Editor |
| Letšoao | The HasRPM and HasPA declarations do not work as visibility constraints for list items in the UTM UI Editor. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | CLS-1127 / CAS-287424-T8R9Q4 |
| Subsystem | Clarius – Data Export |
| Letšoao | A subsite Excel (XLS) file ho tsoa ho sesebelisoa sa ho romela thepa ea Clarius 1.12 ha se tsamaellane le XLS e ka tlase file from Clarius 1.11. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1149 |
| Subsystem | Clarius – Installer |
| Letšoao | Running the installer from an external drive on the 4200A-SCS- causes an error. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1190 |
| Subsystem | Clarius – UTM |
| Letšoao | PMU load-line correction produces different results in UTM compared to ITM/KXCI. |
| Qeto | This issue has been corrected. The UTM correction procedure was synchronized to the correction in ITM/KXCI. |
| Nomoro ea tlhahiso | CLS-1291 / AR-R3J5X9 |
| Subsystem | Clarius - Kerafo |
| Letšoao | The Clarius Graph caused a crash if the user attempted to plot a data series that had a name with special characters. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1334 |
| Subsystem | Clarius - ITM |
| Letšoao | Clarius allows the configuration of an ITM with a PMU pulse timing rule that can generate an endless waveform. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1341 |
| Subsystem | Clarius – CVIV |
| Letšoao | Clarius does not validate the CVIV firmware version properly at launch. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1344 |
| Subsystem | Clarius – Subsite |
| Letšoao | Subsite does not translate subsite run settings when it is exported or imported to Clarius v1.11 format. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1362 |
| Subsystem | Clarius – User Library |
| Letšoao | The flashulib user modules do not accept PMU channels as valid assignments for pulse terminals. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1377 |
| Subsystem | Clarius |
| Letšoao | Clarius crashes when opening a legacy 4200-SCS project with a Calc sheet item that contains long text. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1381 |
| Subsystem | Clarius |
| Letšoao | There is an invalid operation exception for some projects on relaunch of Clarius. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1404 |
| Subsystem | Clarius - Kerafo |
| Letšoao | The Clarius graph crashes when the user adds multiple data series in the configuration dialog. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1429 |
| Subsystem | Clarius - Matha nalane |
| Letšoao | If run history items have custom names and the user selects a new run after opening the test, then deletes the selected run, Clarius test run history may be corrupted. As a result, the graph and grid configuration became corrupted as well. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | CLS-1436 / CAS-339619-M8K5T1 |
| Subsystem | Clarius – Installation |
| Letšoao | Upgrading to V1.13 in some cases may cause 4200A to be in Offline (PC) mode. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1450 |
| Subsystem | Clarius - Kerafo |
| Letšoao | In certain conditions, the Project level graph may lose configured data series after rerunning a test. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1451 |
| Subsystem | Clarius - Kerafo |
| Letšoao | The Clarius graph may lose the configured data series after the first run of the test. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1520 |
| Subsystem | Clarius |
| Letšoao | ITM SMU configuration caused an incorrect sweep step calculation on subordinate SMU sweeper when it is set to dual sweep and the master SMU sweep is a one-way sweeper. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1527 |
| Subsystem | Clarius – Data Export |
| Letšoao | Data Export for a project with partially converted XLS to h5 data files hloleha ho hlahisa files bakeng sa liteko ntle le h5 files. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1565 |
| Subsystem | UTM UI Editor |
| Letšoao | The UTM UI Editor does not save the UTM Image “Expand to Top” configuration setting. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | CLS-1613 / CAS-360140-C2Z7P9 |
| Subsystem | Clarius - ITM |
| Letšoao | Changing an SMU to Voltage Step in some ITMs causes Clarius to crash. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1630 |
| Subsystem | Clarius – Project Graph |
| Letšoao | Data from some ITMs and UTMs is not scaling correctly in the Project Level graph. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1658 |
| Subsystem | Clarius |
| Letšoao | The import of some legacy 4200-SCS KITE projects causes Clarius to hang. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1666 |
| Subsystem | Clarius - Boloka Lintlha |
| Letšoao | When using the Save Test Data dialog, the data file e tla ngoloa haeba mosebelisi a koala "File Already Exist” prompt by selecting the x on the dialog instead of No. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1694 |
| Subsystem | Clarius – Subsite |
| Letšoao | When a subsite is created as E ncha, there are “SMU1-missing” errors in Configure when the subsite is selected. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1745 |
| Subsystem | Clarius – Subsite, Analyze |
| Letšoao | In Analyze, when saving subsite data using Save Data in XLSX format, a file is created with the incorrect cell format. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1760 |
| Subsystem | Clarius - ITM |
| Letšoao | An ITM with configured PMU dual sweeping may generate the error message “sweeping is not properly defined,” even if the configuration is valid. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1763 |
| Subsystem | Clarius – Subsite |
| Letšoao | The Target Type Abs Value Degradation is missing in subsite stress configuration. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1794 |
| Subsystem | KXCI |
| Letšoao | An incorrect error message may be shown in KXCI when calling a user module if the default parameter values contain spaces. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1795 |
| Subsystem | Clarius – Subsite |
| Letšoao | Subsite Linear stressing does not accept values in the range of 0 to 1 s for the first stress time. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1796 |
| Subsystem | Clarius – Subsite |
| Letšoao | Subsite List stressing does not accept values of less than 1 s for the stress time. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1804 |
| Subsystem | Clarius – Project Tree |
| Letšoao | When the Project node is open in the Configure view, Clarius may crash when other project items are deleted. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1814 |
| Subsystem | Clarius – SARB |
| Letšoao | In Clarius v1.13, the maximum number of Seq Loops is limited to 20 in SegArb user modules. It should be up to 2.14E9 loops. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | CLS-1820 / CAS-397328-V2D6Z0 |
| Subsystem | KULT – VS Code Extension |
| Letšoao | The gdb debugger does not attach to the UTMServer.exe process while modifying a UTM in Visual Studio Code. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | CLS-1847 / CAS-326776-V5H0X4 |
| Subsystem | Clarius – Subsite |
| Letšoao | The total test time increases significantly as the number of subsite cycles increases. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1856 |
| Subsystem | Clarius |
| Letšoao | The Messages pane is not visible in Analyze in Clarius v1.13. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1914 |
| Subsystem | Clarius - Kerafo |
| Letšoao | In some circumstances, the Clarius Graph may lose the autoscale settings for the X-axis and Y-axis while running a test. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1943 |
| Subsystem | Clarius - Kerafo |
| Letšoao | Running a UTM after changing the user module selection and setting some valid graph configuration produces an incorrect graph. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1954 |
| Subsystem | Clarius - Kerafo |
| Letšoao | The Clarius Graph fails to add additional curves after running a test with an increased number of steps in a stepper-sweeper test. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1958 |
| Subsystem | Clarius - Kerafo |
| Letšoao | The Clarius Graph may produce inconsistent color, pattern, and data point behavior when selecting runs. |
| Qeto | This issue has been corrected. The Save Settings option was added to the Graph Definition Menu to allow users to save and preserve the present settings of runs in the graph. |
| Nomoro ea tlhahiso | EA-1959 |
| Subsystem | Clarius - Kerafo |
| Letšoao | The Graph Legend gets cut off in some circumstances. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1988 |
| Subsystem | Clarius - Kerafo |
| Letšoao | A Clarius graph with a configured line fit may lose track of the selected data series to plot. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1997 |
| Subsystem | Clarius – Subsite |
| Letšoao | The Clarius subsite graph does not save Log scaling and other configuration settings for its axes. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-1998 |
| Subsystem | Clarius |
| Letšoao | The Save Test Data dialog from Analyze view has a misleading error message if the user saves the graph when graph is not shown. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-2007 |
| Subsystem | Clarius |
| Letšoao | Exporting a Clarius project to a kzp file may cause the test graph to lose the configured data series. |
| Qeto | Taba ena e lokisitsoe. |
| Nomoro ea tlhahiso | EA-2010 |
| Subsystem | Clarius |
| Letšoao | Using the Save As operation may cause the test graph to lose the configured data series. |
| Qeto | Taba ena e lokisitsoe. |
Litaba tse tsebahalang
| Nomoro ea tlhahiso | SCS-6486 |
| Subsystem | Clarius |
| Letšoao | Ho thata ho tsamaisa li-marker tsa line fit u sebelisa the touchscreen. |
| Mokhoa oa ho lokisa | Sebelisa toeba ho tsamaisa matšoao a lekanang. |
| Nomoro ea tlhahiso | SCS-6908 |
| Subsystem | 4215-CVU |
| Letšoao | Ho fiela khafetsa ka lebelo la ho qala ho feta lebelo la ho emisa (fiela fatše) ho ka bala lintlha tse fosahetseng. |
| Mokhoa oa ho lokisa | Ha ho letho. |
| Nomoro ea tlhahiso | SCS-6936 |
| Subsystem | Clarius |
| Letšoao | Ho beha leihlo liteko tsa likanale tse ngata tsa PMU ha ho sebetse. |
| Mokhoa oa ho lokisa | Ha ho letho. |
| Nomoro ea tlhahiso | SCS-7468 |
| Subsystem | Clarius |
| Letšoao | Merero e meng e entsoeng ho Clarius 1.12 e ke ke ea buloa ho sebelisoa Clarius 1.11 le litokollo tsa pele. Ho leka ho bula morero ho Clarius 1.11 ho fella ka melaetsa ea "Corrupted test run history". |
| Mokhoa oa ho lokisa | Sebelisa Clarius 1.12 ho romela morero ho .kzp file ka "Export run data bakeng sa mofuta oa Clarius 1.11 kapa pejana" e lumelletsoe. Kenya projeke ho Clarius 1.11. |
Lintlha tsa tšebeliso
Visual Studio Code Workspace Trust
Ho tloha ka Mots'eanong 2021, Visual Studio Code e bula e ncha file dikhokahano ho Mokhoa o Behiloeng. Likarolo tse ling tsa Visual Studio Code joalo ka ts'ebetso ea khoutu le li-extensions li koaloa ka bohona. Likarolo tse ling tsa software ea Clarius (joalo ka katoloso ea khoutu ea KULT) li ke ke tsa sebetsa ntle le haeba o nolofalletsa Workspace Trust bakeng sa lifoldara tse sebetsang.
Latela sehokelo sena bakeng sa tlhaiso-leseling e batsi mabapi le ho tšepa libaka tsa ts'ebetso, ho nolofalletsa likhoutu katoloso, le lihlooho tse ling tse amanang le Mokhoa o Behiloeng: https://code.visualstudio.com/docs/editor/workspace-trust
4200A-CVIV
Pele u sebelisa Model 4200A-CVIV Multi-Switch, etsa bonnete ba hore u hokahanya li-SMU u sebelisa li-module tsa 4200-PAs le 4200A-CVIV-SPT SMU Pass-Thru, le lisebelisoa tsa CVU ho lisebelisoa tsa 4200A-CVIV. Etsa bonnete ba hore o koala kopo ea Clarius pele o bula KCon komporong ea hau. Ebe u tsamaisa Update Preamp, RPM, le khetho ea CVIV Configuration ho KCon. Kenyelletsa ts'ebetso ea cviv-configure pele ho tlhahlobo ea SMU kapa CVU sefateng sa morero ho fetola pakeng tsa litekanyo tsa IV le CV.
4225-RPM
Pele o sebelisa 4225-RPM Remote Amplifier Switch Module ho switjha lipakeng tsa IV, CV, le Pulse ITMs, etsa bonnete ba hore o hokela lithapo tsohle tsa lisebelisoa ho kenya RPM. Etsa bonnete ba hore o koala kopo ea Clarius pele o bula KCon komporong ea hau. Ebe u tsamaisa Update Preamp, RPM, and CVIV Configuration option in KCon. When using the 4225-RPM in UTMs, include the call in your user module to the LPT command rpm_config(). The RPM_switch user module in the pmuulib user library is deprecated. For more information, see the Help pane in Clarius.
4210-CVU kapa 4215-CVU
When choosing the Custom Cable Length in the CVU Connection Compensation dialog box of the Tools menu to perform open, short, and load simultaneously, you must run Measure Custom Cable Length first. Then enable Open, Short, and Load CVU Compensation within a test. If you are performing Open, Short, and Load CVU Compensation when the CVU is connected to the 4200A-CVIV, a best practice is to use the cvu-cviv-comp-collect action.
4200-SMU, 4201-SMU, 4210-SMU, kapa 4211-SMU
Tlas'a maemo a itseng, ha ho matha SMU hona joale fiela ka lebelo haholo ramp litefiso, SMU e ka tlaleha ho lumellana ha eona ho sa lebelloa. Sena se ka etsahala haeba ho fiela ramps are too high or too fast. The workarounds for this situation are:
- Use the setmode command when generating user modules to turn off the compliance indicator value. With this workaround, the reading is returned as 105% of the present range.
- Sebelisa ho fiela tse nyane le ramp litefiso (dv/dt kapa di/dt).
- Use fixed SMU ranges.
LPTLIB
- Haeba voltagho hlokahala moeli o moholo ho feta 20 V ho tsoa ho SMU e behiloeng ho qobella lefela hona joale, mohala oa measv o lokela ho sebelisoa ho seta SMU hore e iketsetse boemong bo phahameng kapa e behe molumo o phahameng.tage na le rangev.
- Haeba moeli oa hajoale oa ho feta 10 mA o hlokahala ho tsoa ho sete ea SMU ho qobella li-volts tsa zero, mohala oa measi o lokela ho sebelisoa ho seta SMU hore e ikemisetse ho ea sebakeng se phahameng kapa ho beha sebaka se phahameng sa hajoale ka rangei.
KULT
Haeba o fetola kapa o hloka ho aha ki82ulib bocha, ka kopo hlokomela hore ki82ulib e ipapisitse le ki590ulib le Winulib. U tlameha ho hlakisa litšepeho tsena ho Likhetho > Litšepiso tsa Laebrari ho KULT pele u haha ki82ulib. Khetho > Haha Laeborari mosebetsi o tla hloleha haeba litšepeho li sa khethoa ka nepo.
KXCI
Ho Mokhoa oa Sistimi oa KXCI, ho emulation ea KI4200A le HP4145 emulation, ho na le mekhahlelo e latelang ea litekanyo tsa hajoale:
- Limited Auto – 1 nA: The default current measurement range for 4200 SMUs with preamplifiers.
- Limited Auto – 100 nA: The default current measurement range for 4200 SMUs without preamplifiers.
Haeba ho hlokahala sebaka se fapaneng se ka tlase, sebelisa taelo ea RG ho beha mocha o boletsoeng sebakeng se tlase. Example: RG 1,1e-11 This sets SMU1 (with preamplifier) ho Limited Auto - 10 pA range
Phoso ea drive ea netweke ea Microsoft® Windows® e mapped
Ha o kenya Clarius + khomphuteng ea hau, litlhophiso tsa leano la Microsoft li ka fokotsa Clarius + ho fihlella li-drive tsa marang-rang tse nang le 'mapa ho eona. file lifesetere. Ho fetola registry ho tla lokisa taba ena. Ho fetola registry:
- Matha regedit.
- Navigate to HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\System.
- Haeba e le sieo, theha sengoloa se secha sa DWORD se bitsoang EnableLinkedConnections.
- Beha boleng ho 1.
- Qala komporo hape.
Ho kenya lik'homphieutha, lipakete tsa lipuo
Clarius+ ha e tšehetse lipuo tse ling ho Microsoft Windows 10 ntle le puo ea motheo ea Senyesemane (United States). Haeba u kopana le liphoso ka Clarius + ha pakete ea puo e kentsoe, latela litaelo tsa Microsoft bakeng sa ho tlosa pakete ea puo.
Litaelo tsa ho kenya
Litaelo tsena li fanoe e le litšupiso haeba u hloka ho kenya software ea Clarius+ hape ho 4200A-SCS ea hau. Litefiso tsohle tsa CVU Open, Short, and Load li tlameha ho fumanoa hape kamora hore mofuta oa morao-rao o kenngoe. Haeba u kenya Clarius + le ACS tsamaisong e le 'ngoe, Clarius + e tlameha ho kenngoa pele. Haeba u sebelisa KULT Extension, u tlameha ho tlosa le ho kenya KULT Extension ka mor'a ho kenya Clarius +.
MOHATO OA 1. Boloka boitsebiso ba polokelo ea mosebedisi bo fetotsoeng (boikhethelo)
Ho kenya software ea Clarius+ ho kenya hape C:\S4200\kiuser\usrlib. Haeba u entse liphetoho laebraring ea basebelisi 'me u sa batle ho lahleheloa ke liphetoho tsena ha software ena e kentsoe, kopitsa tsena files to an alternate location before installation. The easiest way to archive the user library is to copy the entire C:\S4200\kiuser\usrlib folder to a network drive or an archive area on the 4200A-SCS hard drive. Copy the files morao ka mor'a ho kenya ho tsosolosa tsona.
MOHATO 2. Tlosa 4200A-SCS Clarius + Software Tools
Pele o kenya Clarius+, o hloka ho hlakola mofuta o teng o sebelisa Windows Control Panel. Haeba u ntse u ntša mofuta oa Clarius+ hamorao ho feta V1.12 'me u rera ho kenya mofuta oa pejana, o hloka ho fetolela merero ho tsoa ho data ea HDF5. file fomete ho sebopeho sa data sa Microsoft Excel 97 .XLS.
Hlokomela :Haeba u batla ho romella data ea kantle bakeng sa tšebeliso ea mofuta oa pejana oa Clarius + ntle le ho e hlakola, o ka sebelisa khetho ea Projects> Export. Sheba sehlooho se reng "Export a project" Setsing sa ho Ithuta bakeng sa lintlha tse ling.
To uninstall Clarius+:
- From Start, select Windows System > Control Panel.
- Select Uninstall a program.
- Select Clarius+.
- For the prompt “Do you want to completely remove the selected application and all of its features?”, select Yes.
- Ho Convert Data Files dialog, ha o batla ho:
- Install a version prior to v1.12: Select Yes.
- Reinstall v1.12 or a later version: Select No.
- Kamora ho qeta mokhoa oa ho hlakola, kenya Clarius+ joalo ka ha ho hlalositsoe ho lintlha tsa tokollo bakeng sa mofuta oo u o kenyang.
MOHATO 3. Kenya 4200A-SCS Clarius + Software Tools
U ka khoasolla software ea Clarius + ho tsoa ho tek.com websebaka. Ho khoasolla le ho kenya software ea Clarius + ho tsoa ho websebaka:
- Eya ho tek.com.
- Select the Support link.
- Select Find Software, Manuals, FAQs by Model.
- In the Enter Model field, enter 4200A-SCS.
- Tlanya E-ea.
- Khetha Software.
- Khetha mofuta oa software.
- Select the software link that you want to download. Note that you will need to log in or register to continue.
- Unzip e jarollotsoeng file to a folder on the C:\ drive.
- Tobetsa habeli setup.exe file ho kenya software ho 4200A-SCS ea hau.
- Follow the on-screen installation instructions. If a previous version of Clarius+ software is installed on your 4200A-SCS, you will be asked if you want to remove it. When asked, select OK to continue; selecting No will abort the installation. If a previous version of Clarius+ software is uninstalled, you must restart the system and then install the new Clarius+ software version.
- After the installation is complete, select Yes, I want to restart my computer now to restart the 4200A-SCS before attempting to initialize or use the software tools.
MOHATO 4. Qala akhaonto e 'ngoe le e 'ngoe ea 4200A-SCS ea mosebedisi
Each user account on the 4200A-SCS must be properly initialized before attempting to run any of the Clarius+ software tools. Failure to initialize may cause unpredictable behavior. From the Microsoft Windows login screen, type the user name and password of the account to be initialized. This must be done for each of the two default Keithley factory accounts, and for any additional accounts added by the system administrator. The two factory accounts are:
| Lebitso la mosebedisi | Password |
| ngoana | ngoana1 |
| kiuser | kiuser1 |
Ha Windows e qetile ho qala, khetha Qala > Keithley Instruments > Qala Mosebelisi e Mocha. Sena se qala mosebelisi oa hajoale.
Pheta mehato e le 'ngoe le tse peli bakeng sa li-account tsa Keithley le li-account life kapa life tse ling tse kentsoeng ke motsamaisi oa sistimi.
Hlokomela
Setsi sa ho Ithuta se thehiloeng ho HTML5 ha se tšehetsoe ho Internet Explorer. Ho kenya ho tla kenya Microsoft Edge Chromium, empa ho ka 'na ha hlokahala hore u fetole sebatli sa kamehla ho li-account tsa mosebedisi tse nang le "default set to Internet Explorer". U ka sebelisa e 'ngoe ea libatli tse latelang: Microsoft Edge Chromium, Google Chrome, kapa Firefox.
MOHATO 5. Ntlafatsa 42×0-SMU, 422x-PxU, 4225-RPM, 4225-RPM-LR, 4210-CVU, le 4200A-CVIV firmware
- Software ea Clarius e hlahloba lisebelisoa tsa firmware tse tsamaellanang nakong ea ho qala 'me ha e sebetse haeba lisebelisoa tsohle li sa ntlafatsoe ho liphetolelo tsa firmware tse lumellanang.
- Ho fumana mofuta oa hajoale oa hardware le firmware ea likarete tsa hau tsa 4200A-SCS, sebelisa sesebelisoa sa KCon ebe u khetha karete ka 'ngoe.
- Lenaneo la ntlafatso ea firmware le bontša ka bo eona hardware e hlokang ho ntlafatsoa ho mofuta o amohelehang kapa oa morao-rao oa firmware.
- Likarete tsa 4200A-SCS li hlophisitsoe ke malapa a mefuta e amanang le eona, joalokaha ho bontšitsoe ho tse latelang.
Ho ntlafatsa firmware ea likarete tsa hau tsa 4200A-SCS:
Ho khothaletsoa ka matla hore o hokahane le 4200A-SCS ho phepelo ea motlakase e sa senyeheng nakong ea ts'ebetso ea ntlafatso ea firmware. Haeba matla a lahlehile nakong ea ntlafatso ea firmware, lisebelisoa li ka 'na tsa se ke tsa hlola li sebetsa' me li tla hloka tšebeletso ea fektheri.
- Exit all Clarius+ software programs and any other Microsoft Windows programs.
- From the Windows taskbar, select Start.
- In the Keithley Instruments folder, select the Firmware Upgrade tool.
- If your instrument needs to be upgraded, the upgrade button becomes visible and there is an indication in Status that an upgrade is required for an instrument, as shown below.
- Kgetha Ntlafatsa.
Puisano ea Firmware Upgrade Utility e ka tlase e bontša hore ntlafatso ha ea phetheha. CVU1 e hloka ntlafatso.
Lethathamo la "Firmware Upgrade Utility".
Tafole ea phetolelo
| Lelapa la lisebelisoa tsa 4200A-SCS | Mofuta oa Hardware ho tsoa ho KCon | Mofuta oa Firmware |
| 4201-SMU, 4211-SMU, 4200-SMU,
4210-SMU1 |
05,XXXXXXXX kapa 5,XXXXXXXX | H31 |
| 06,XXXXXXXX kapa 6,XXXXXXXX | M31 | |
| 07,XXXXXXXX kapa 7,XXXXXXXX | R34 | |
| 4200-PA | Sehlahisoa sena se ke ke sa ntlafatsoa sebakeng sa marang-rang |
- |
| 4210-CVU | KAOFELA (3.0, 3.1, 4.0, le hamorao) | 2.15 |
| 4215-CVU | 1.0 le hamorao | 2.16 |
| 4220-PGU, 4225-PMU2 | 2.XX only | 2.08 |
| 3.XX only | 3.00 | |
| 4225-RPM, 4225-RPM-LR | 1.0 le hamorao | 2.00 |
| 4200A-CVIV3 | 1.0 | 1.05 |
| 4200A-TUM | 1.0 | 1.0.0 |
| 1.3 | 1.1.30 |
- Ho na le mefuta e mengata e fapaneng ea li-SMU tse fumanehang ho 4200A-SCS: 4201-SMU kapa 4211-SMU (matla a mahareng) le 4210-SMU kapa 4211-SMU (matla a phahameng); bohle ba sebelisa firmware e tšoanang file.
- 4225-PMU le 4220-PGU li arolelana pulse le boto ea mohloli. 4225-PMU e eketsa bokhoni ba tekanyo ka boto e eketsehileng ea lisebelisoa empa e sebelisa firmware e tšoanang file.
- Firmware ea 4200A-CVIV e na le tse peli files ho ntlafatsa. Sesebelisoa sa firmware se sebelisa ka bobeli files foldareng ea mofuta.
FAQs
Where can I find detailed installation instructions for Clarius+ software?
Detailed installation instructions are provided in the Version table section of the document.
How can I optimize the performance of Clarius+ software?
Refer to the Usage notes section for helpful information on optimizing performance.
What is the latest software version available for Clarius+?
The latest software version is v1.14 as of April 2025.
Litokomane / Lisebelisoa
![]() |
KEITHLEY 4200A-SCS Parameter Analyzer Clarius Plus [pdf] Bukana ea Mosebelisi 4200A-SCS, 4200A-CLARIUS-V1.14, 4200A-SCS Parameter Analyzer Clarius Plus, 4200A-SCS, Parameter Analyzer Clarius Plus, Analyzer Clarius Plus, Clarius Plus |