Elitech RCW-360 Pro Temperature Humidity Data Logger

Elitech iCold Platform: new.i-elitech.com

FEELAVIEW
Sehlahisoa sena ke marang-rang a marang-rang a marang-rang a marang-rang, a fanang ka mesebetsi e kang ho shebella nako ea sebele, alamo, ho rekota data, ho kenya data, pontšo e kholo ea skrine, joalo-joalo ea mocheso le mongobo libakeng tsa ho shebella. Hammoho le "Elitech iCold" sethaleng le APP, e ka hlokomela mesebetsi e kang data e hōle. viewing, query data query, remote alarm push, joalo-joalo E sebelisoa haholo indastering ea lijo, meriana, phepelo, polokelo ea thepa ea machaba le ea thepa.
Likaroloana
- Sehlahisoa se loketse liketsahalo tse fapa-fapaneng, ho kenyeletsa ntlo ea polokelo, polokelo ea sehatsetsing, koloi ea sehatsetsing, khabinete ea moriti, khabinete ea meriana, lab ea sehatsetsing, joalo-joalo;
- Boholo bo kopaneng, ponahalo ea feshene, moralo oa tray ea karete ea makenete, ho kenya habonolo;
- Pontšo e kholo ea skrine ea mebala ea TFT, e nang le litaba tse ngata;
- Betri ea lithium e kentsoeng ka hare ho eona e nolofalletsa ho kenya data ea nako e telele ka mor'a ho khaola matla;
- Sesebelisoa sa alamo se hahelletsoeng kahare se ka lemoha alamo ea lehae;
- Automatic screen-on/off;
- Supports up to 2 channels, each channel supports a variety of pluggable probe types, probe types see the selection list.
Sehokedi

- Patlisiso ea kantle 1
- Konopo ea ho tima/ho tima
- Terei ea karete ea Magnetic
- SIM card interface(4G Version)
- Sehokelo sa ho tjhaja
- External Probe 1 Interface
- Letšoao la ho tjhaja
- Letšoao la boemo ba alamo
- Skrine
- Patlisiso ea kantle 2
- Konopo ea "Menu".
- External Probe 2 Interface
Lethathamo la Khetho ea Mehlala
Malebela: The specific host model is subject to the actual product;
Mohlala oa probe: The conventional probe models are shown in the table below:

Hlokomela:
- The specific sersor type is subject to the actual product.
- The host does not come standard with probes. Please choose probes according to actual needs, and each channel can adapt to the above types of probes.
Tekheniki Parameters
- Power input: 5V/2A (DC), Type-C.
- Temperature display resolution: 0.1°C.
- Humidity display resolution: 0.1%RH.
- Number of offline recording groups: 100,000.
- Data storage mode: circular storage.
- Record, upload interval and alarm interval:
- Normal recording interval: 1 minutes ~ 24 hours allowed, Default 5 minutes.
- Alarm recording interval: 1 minutes ~ 24 hours allowed, Default 2 minutes.
- Normal upload interval: 1 minutes ~ 24 hours allowed, Default 5 minutes.
- Alarm upload interval: 1 minutes ~ 24 hours allowed, Default 2 minutes.
- Bophelo ba betri:
- Not less than 10 days (@25°C, good network environment, upload interval :5 minutes)
- Not less than 60 days (@25°C, good network environment, upload interval :30 minutes)
- Indicator light: alarm indicator, charging indicator.
- Screen: TFT color screen.
- Buttons: power on/off, menu.
- Alarm buzzer: alarm occurs, sounding for 1 minute.
- Communication: 4G(can fall back to 2G),WIFI.
- Location mode: LBS+GPS(optional).
- Alarm modes: local alarm and cloud alarm.
- Waterproof grade: IP64.
- Working environment: -20~60 °C, 0~90% RH (non-condensing).
- Specification and dimension: 110x70x23mm.
Litaelo tsa Ts'ebetso
Installing and removing the probe
Turn off the device and securely install the sensor to the headphone connector. To remove the sensor, please turn it off first and then unplug the sensor.
Ho tjhaja
Connect to the power adapter via USB cable. When charging, the charging indicator flashes; when it is fully charged, the charging indicator is always on.
Matla a ho bulela/ tima
Press and hold the on/off button for 3 seconds to turn on or off the device. Start recording data according to the recording interval after turning on, and report data according to the upload interval. Stop recording after turn off.
Lintlha tsa nako ea sebele

- Networking signal icon: Connect to the base station and display a signal bar. If the device networking is abnormal, an “X” will be displayed in the upper left corner of the signal.
- Channel identification: Represented by CH1 or CH2, indicating the probe data corresponding to channel 1 or 2 for the current data.
- Real time temperature or humidity: Supports °C or °F display. If the platform turns off the probe, the corresponding position will display “OFF”.
- Upper and lower alarm limits: The data below the lower limit will be displayed in blue, and the data above the upper limit will be displayed in red.
- Number of data not uploaded: Displays the number of recorded but not uploaded data.
- Battery icon: Four-bar battery indicator. When charging, the battery indicator flashes and remains on when fully charged. When the battery level is below 20%, it is displayed in red.
- Time and date. When both channels are connected with probes, the CH1 and CH2 channel data automatically switches display within 10 second cycle.
Boholo le Bonyane
Short press the “Menu” key to enter the “Maximum and Minimum” page, as shown in the following figure. Count the maximum and minimum values in the recorded data. CHA and CH1B represent the two collected values of channel 1 or 2, corresponding to sensor shutdown or single temperature probe. The B data displays “-~=”.
Viewing records and uploading intervals
Short press the “Menu” button to enter the “Record and Upload Interval” page, as shown in the following figure, which can be set through the APP.
View lintlha tsa sesebelisoa
Press the “Menu” button to enter the “Device Information” page, as shown in the following figure. You can query the model, Sensor, version, GUID, IMEI, SIM card ICCID (only for Wi-Fi version)
Adding devices to the platform and basic operations
Adding decices to the platform and operation, please refer to “IV Elitech iCold”.
Elitech iCold
Sethala sa Elitech iCold Cloud se tšehetsa mekhoa e 'meli ea ho eketsa le ho laola lisebelisoa: APP kapa WEB moreki. Se latelang se hlahisa haholo-holo mokhoa oa APP. WEB client can log in to new.i-elitech.com bakeng sa ts'ebetso.
Khoasolla le ho kenya APP
Please scan the QR code on the cover of the manual or search the Elitech iCold APP Store or Google Play to download the Elitech App.
Account registration and APP Login
Open the APP, in the login page, as shown in Figure 1, follow the prompts, enter the verification information, and click “Login”. After entering the APP, select ” New”.
PS
- If you have not an account, please click on “Register” in the login page, as shown in Figure 2, follow the prompts, and enter verification information to complete account registration.
- If you forget the password, click “Forget password” to find password as shown in Figure 3. According to the prompts to finish verification and find outthe password.

Kenya Sesebelisoa
- Tobetsa “
” hukung e kaholimo ho le letona - Tobetsa
“” in the upper right corner, scan the QR code or enter GUID back on the device, then fill in the device name and choose time zone. - Tobetsa “Add”, the device is added.

Keletso: If the device shows offline after being added to the platform, first check the network icon and offline records on the device. If everything is normal, please wait for a few minutes or restart the device before turning it on. The device uploads data according to the set reporting cycle; If the device is offline for a long time, please check if the SIM card is overdue. Ultimately unable to resolve, please call the service hotline for consultation.
WIFI distribution network(WIFI version only)
- Press the “Menu” key briefly to enter the “device Information” page.

- Press and hold the “Menu” key, and a Bluetooth icon "Bluetooth “will appear in the upper left corner of the device

Hlokomela: Please do not exit this page during the distribution network process. - Use the app to distribute the network with this device via Bluetooth, as shown in the following figures 1 ~ 4.

Configure probe type
When using the device for the first time or changing the probe type, it is necessary to reconfigure the probe, as shown in Figure 4 and Figure 5 for operation;
Mokhoa oa ts'ebetso: Log in to the APP → select the device to be changed → select “Parameter Configuration” → select “User Parameters” → select the corresponding probe model based on the actual selected probe type and channel → click “SET”.
Hlokomela
- After reconfiguring the probe type, it is necessary to wait for an upload cycle to synchronize e probe type to the device, or the device can be restarted to synchronize immediately.
- Replace the probe. Due to the time difference between replacing the probe and configuring it, there may be faulty data in the data list.
Tsamaiso ea lisebelisoa
Click on the device on the main page of the APP to enter the device management-related page. You can view lintlha tsa sesebelisoa, fetola mabitso a sesebelisoa, view lethathamo la data, beha meeli ea alamo e holimo le e tlase, nako ea ho rekota / ho kenya, lokisa push push, view limmapa, litlaleho tsa thomelontle, le mesebetsi e meng.
Elitech iCold Platform
For more functions, please log in to Elitech iCold Platform: new.i-elitech.com.
Phahamiso
Free data & advanced platform service will be activated after the device be first time registered to the Elitech platform. After the probation period, customers need to recharge the device by referring to operation manual.
Lipotso Tse Botsoang Hangata
P: Ke mefuta efe ea li-probe e lumellanang le sesebelisoa see?
A: The compatible probe types are listed in the provided selection list in the manual.
P: Ke fumana lintlha tsa nalane joang ke sebelisa sethala sa Elitech iCold?
A: You can access historical data by logging into the Elitech iCold platform or using the accompanying APP for remote data viewle lipotso tsa histori tsa data.
Litokomane / Lisebelisoa
![]() |
Elitech RCW-360 Pro Temperature Humidity Data Logger [pdf] Bukana ea Mosebelisi RCW-360Pro, RCW-Pro 4G-WiFi, RCW-360 Pro Temperature Humidity Data Logger, RCW-360, Pro Temperature Humidity Data Logger, Humidity Data Logger, Data Logger |