Sehlahisoa se Felletseview le Ponahalo

RC-4 Pro is a recorder used for recording temperature and humidity data during the transportation of food, drugs, chemicals, and other products. It is widely used in various transportation links such as warehousing and logistics, such as containers, refrigerated trucks, refrigerated containers, cold storage, and so on. By using a single button to start/stop recording, you can flip through pages to view various interfaces. Powered by a Single CR2450 battery for easy replacement, Transfer data to the “Jingchuang Data Center” management software through the Type-C interface. And the software can export files ka liforomo tse kang PDF, EXCEL, TXT, joalo-joalo.

Sehlahisoa se Felletseview

  1. Moea oa moea
  2. LCD skrine
  3. Ho hlahloba ka ntle
  4. letlapa la dikonopo
  5. Buzzer
  6. Type-CC interface
  7. Mokoti oa thapo o leketlileng
  8. Letlapa la lebitso la lisebelisoa
  9. Sekoaelo sa betri

Litekanyetso tsa tekheniki

Litaelo tsa ts'ebetso

Activate the recorder
Tlosa letlapa la insuela le matla holim'a sehatisi.

Elitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (3)

Install sensors (according to actual needs)
Install sensors according to the requirements, and configure them through the Jingchuang Data Center before enabling the external probe function.

Elitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (4)

Kenya software
Please download and install the Jingchuang Data Center software through www.elitechlog.com.

Lokisa liparamente
Connect the recorder to the computer via a USB cable and wait Elitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (5) until the symbol appears on the screen. Software configuration: If you do not need to modify the default parameters, please click on the Summary menu> Quick Reset button. Can synchronize local time; if there is a need to modify parameters, please click on the Configure Device menu, change parameters, and click Save Parameters to complete the configuration.

Hlokomela! To avoid time/time zone errors, please be sure to click on the quick reset or save parameters before first use or after replacing the battery to ensure that the local time is configured in the recorder. Exceeding the limit and shortening the recording interval parameter: By default, to is prohibited; If changed to allow, the recording interval will be automatically shortened to once every 1 minute after the humidity exceeds the limit.

Qala ho rekota
Press and hold the button for 5 seconds to activate the recording, and the symbol Elitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (6)appearing on the screen indicates successful activation.
Hlokomela! The continuous flashing of the symbol indicates that the recorder is set with a startup delay. It will start recording after the end of the delayed startup.

Pause the recording
Click the button, and when the Log interface appears, double-click the button. When a symbol Elitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (7)appears on the screen, it represents a pause in recording.
Hlokomela! The pause function can only be used after being configured through the data center software.

Emisa ho rekota
Stop recording: Press and hold the button for 5 seconds, and the symbolElitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (8)appearing on the screen indicates a successful stop.
Hlokomela! The stopping method can be configured through the data center software.

Khoasolla lintlha
Connect the recorder to the computer via a USB cable and wait until the symbol Elitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (5) e hlaha skrineng.
Setsi sa data: The data will be automatically uploaded. Click the export button to select the file format to export the report; If it is not automatically uploaded, please manually click the download button and repeat the operation.
USB drive: directly export the corresponding report file.;

Sebelisa hape
Khaotsa ho hokela sehatisi khomphuteng, boloka kapa u romele kantle ho data/litlaleho, 'me u phete mehato ea 4. Lokisa liparamente le 5. Qala ho rekota.

Hlokomela! After saving the parameters, the recorded historical data will be cleared. If you forget to save/export data, you can view and manage it
The device accessed ice through the historical data menu of the data center software.

Pontsho ya boemo

Functions of the keypad

Elitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (9)

Skrine se seholo

Elitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (10)

  1. Boemo ba betri
  2. E emisitsoe
  3. Ho rekota
  4. USB e hokahane
  5. Upper and llower limits
  6. Sesebelisoa sa buzzer
  7. Recording groups
  8. Kgwedi
  9. Boholo. boleng
  10. Min. boleng
  11. Letsatsi
  12. Theko e tloaelehileng
  13. Sebaka sa data
  14. Peresentetage
  15. Setsi sa data

Boemo ba betri

Elitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (11)Hlokomela: When the battery level is less than 10%, please replace the battery as soon as possible.

Phetoho ea betri

Elitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (12)

  1. Bula sekwahelo sa betri.
  2. Tlosa betri ea khale
  3. Install a new CR2450 battery and place it in the battery compartment
  4. Koala sekoaelo sa betri.

Lenane la lihlahisoa

  • Mohatisi×1
  • Mohala oa data oa USB ×1
  • External mocheso probe×1
  • 3V konopo ea betri (CR2450) x 1

Mehato ya tlhokomelo

  1. Please store the recorder in a room-temperature environment.
  2. When using the recorder for the first time, please make sure to use the Jingchuang Data Center software for the parameter configuration to synchronize system time.
  3. Please do not remove the battery during the recording process of the recorder.
  4. If there is no button operation for 15 seconds, the recorder will automatically turn off the screen. Click the button to reset the battery screen.
  5. After each parameter reconfiguration of the recorder, the previously recorded data will be cleared. Please export the data before saving the parameters;
  6. To ensure humidity accuracy, please avoid contact with unstable chemical solvents or other chemical substances, especially avoid long-term presence or exposure to high concentrations of ketones, acetone, ethanol, isopropanol, toluene, and other environments.
  7. The battery symbol on the screen is below one square ( Elitech-RC-4-Pro-Digital-Temperature-Data-Logger-fig- (13)). Please do not use it for long-distance transportation
  8. Propylene glycol liquid is used inside the probe of the gel bottle to simulate the temperature change inside the vaccine, which is more suitable for medical use scenarios.

Litokomane / Lisebelisoa