📘 SIMARINE manuals • Free online PDFs
SIMARINE letšoao

SIMARINE Manual & Litaelo tsa Basebelisi

SIMARINE manufactures advanced battery monitoring systems and digital switching solutions designed for the marine and recreational vehicle markets.

Keletso: kenyelletsa nomoro e felletseng ea mohlala e hatisitsoeng leiboleng la hau la SIMARINE bakeng sa ho bapisa hantle.

About SIMARINE manuals on Manuals.plus

SIMARINE is a specialized electronics developer focused on high-precision battery monitoring and digital switching systems for the marine and caravan industries. Based in Slovenia, the company is best known for its PICO battery monitor, which sets a new standard in design and functionality by providing detailed insights into battery health, tank levels, and temperatures.

With a philosophy grounded in energy efficiency and user-friendly design, SIMARINE offers a comprehensive ecosystem of digital shunts, tank modules, and inclinometers. Their products enable boat and RV owners to easily manage complex electrical systems through intuitive indicators and mobile app integration, ensuring safety and reliability during travel.

Libuka tsa tataiso tsa SIMARINE

Libukana tsa morao-rao tse tsoang ho manuals+ e etselitsoeng mofuta ona.

SIMARINE STR-2 Radar Tank Level Sender User Manual

La 8 Phupu 2026
STR-2 Radar Tank Level Sender SIMARINE STR-2 Radar Tank Level Sender Overview The SIMARINE STR-2 is an NMEA2000-compatible radar tank level sender designed for accurate liquid level monitoring. It transmits…

SIMARINE Light Switch User Manual

La 8 Phupu 2026
SIMARINE Light Switch User Manual Introduction Simarine's Light Switch is a Multifunctional 12V DC double switch with integrated dimmers. The Multifunctional switch can be used in all 12V DC installations…

SIMARINE STR2 Radar Tank Level Sender User Manual

La 8 Phupu 2026
SIMARINE STR2 Radar Tank Level Sender Technical specification IP rating IP67 Operating Operating voltage 8 - 35 VDC Operating temperature range -20°C – 70°C ( -4°F – 158°F) Tank size…

SIMARINE STR1,STR2 Tank Adapter Installation Guide

La 28 Phuptjane 2026
SIMARINE STR1,STR2 Tank Adapter Specifications Compatibility: SIMARINE STR1 and STR2 Tank Adapters Included Components: 1x STR Adapter 1x Sealant 5x M10 Bolts Material: Plastic adapter, Rubber seal Application: Tank mounting…

SIMARINE SC503 Combo Shunt Modules Buka ea Mosebelisi

La 25 Pulungoana 2025
Litlhaloso tsa Li-module tsa SIMARINE SC503 Combo Shunt Model: SC303 & SC503 Moetsi: Mesebetsi ea Simarine: Litekanyo tsa voltage, current, and temperature of the battery or battery bank, monitors current draw of heavy…

SIMARINE SC303 Dometic Mobile Power User Manual

La 3 Phuptjane 2025
SIMARINE SC303 Dometic Mobile Power Litlhaloso tsa tekheniki SC303 & SC503 SC303 Operating Voltage range 6 - 35V Temperature range -20°C – 70°C (-4°F – 158°F) Power consumption at…

Simarine STR1 Manuale d'Uso

tataiso
Manuale d'uso per il trasmettitore di livello radar per serbatoi Simarine STR1. Include istruzioni per l'installazione, il cablaggio, la calibrazione e la configurazione tramite Bluetooth.

Nereide 2 Digital Switching User Manual

tataiso
User manual for the Simarine Nereide 2 Digital Switching system, including installation, configuration, and operation instructions for the SCP-210 panel and SPU-303 distribution unit.

Simarine Light Switch User Manual

tataiso
User manual for the Simarine Light Switch, a multifunctional 12V DC double switch with integrated dimmers. Includes installation, configuration, and technical specifications.

SIMARINE manuals from online retailers

Buka ea Mosebelisi ea Simarine Pico One Battery Monitor Set

pico_one • July 9, 2025
Bukana e felletseng ea mosebelisi bakeng sa Sete ea Monitor ea Battery ea Simarine Pico One. Ithute ka ho kenya, ts'ebetso, likarolo le ho rarolla mathata bakeng sa li-vol tse ngatatagLitsamaiso tsa ho beha leihlo betri, tanka le mocheso.

SIMARINE support FAQ

Lipotso tse tloaelehileng mabapi le libuka, ngoliso, le tšehetso ea mofuta ona.

  • Why is my Simarine shunt not visible on the PICO unit?

    If the shunt is not visible, check that it is properly connected via the SiCOM port using a twisted pair cable. Ensure the voltage sensing input is correctly installed and terminals are not switched.

  • What should I do if the current value shows a wrong sign?

    If the current value is negative when it should be positive (or vice versa), the shunt may be installed backwards. Ensure the battery minus terminal connects to the 'IN' terminal on the shunt, or switch the configuration via the PICO menu.

  • How do I calibrate a tank sensor on the Simarine system?

    Tank sensors must be calibrated via the PICO menu or the Simarine mobile app to show the correct levels. Refer to the PICO manual for the specific calibration procedure for your sensor type.

  • What type of cable is recommended for the SiCOM connection?

    For SiCOM connections longer than 5 meters, it is recommended to use a 2x2x0.25 mm2 twisted pair cable to ensure reliable data transmission.