Rongta RLS1100C Barcode Scale Buka ea mosebelisi
Model: RLS1100C
1. Selelekela
This manual provides detailed instructions for the proper operation, maintenance, and troubleshooting of your Rongta RLS1100C Barcode Scale. Please read this manual thoroughly before using the device to ensure optimal performance and longevity.
Likarolo tsa Bohlokoa:
- Maximum weight capacity of 30 kg.
- High precision with 5-gram graduation.
- Fast printing speed of 80 mm/second.
- Equipped with Network and Serial RS232 ports for versatile connectivity.
- Large storage capacity for up to 10,000 items.
- User-friendly panel with 112*2 shortcuts.
- Features a clear, backlit LCD display.
- Supports full Arabic language for printing and display.
- Includes free software for item uploading and label design.
2. Seta
2.1 Ho phutholla le ho hlahloba
Carefully remove the scale from its packaging. Inspect all components for any signs of damage during transit. Ensure all accessories listed in the packing list are present.
2.2 Ho bea
Place the scale on a stable, flat, and level surface. Avoid locations with excessive vibration, direct sunlight, or extreme temperature fluctuations. Ensure adequate space around the scale for operation and ventilation.
2.3 Khokelo ea Matla
Connect the power adapter to the scale's power input port and then plug it into a standard 100-240V, 50-60Hz electrical outlet. Ensure the power switch is in the OFF position before connecting.
2.4 Label Roll Installation
Open the label compartment. Insert the label roll, ensuring the labels feed correctly through the printer mechanism. The scale supports label widths from 30mm to 60mm and a maximum roll diameter of 10cm.

Setšoantšo: Pele view of the Rongta RLS1100C Barcode Scale, showing the main display, weighing platter, and keypad for item entry and shortcuts.
3. Litaelo tsa Ts'ebetso
3.1 Ho Matlafatsa/Ho tima
To power on the scale, flip the power switch located on the side or rear of the device to the 'ON' position. The display will light up and perform a self-test. To power off, flip the switch to 'OFF'.
3.2 Tekanyo ea Motheo
- Ensure the scale displays '0.000 kg' before placing any item.
- Gently place the item to be weighed on the center of the weighing platter.
- Bala boima bo hlahang skrineng.
3.3 Taring Function
To weigh an item in a container, first place the empty container on the platter. Press the TLALI button. The display will reset to '0.000 kg'. Now, place the item inside the container, and the scale will display only the net weight of the item.
3.4 Item Programming and Label Printing
The scale supports programming up to 10,000 items. Use the provided free software to upload item data (PLU - Price Look-Up) including item name, unit price, and other relevant information. Once programmed:
- Place the item on the weighing platter.
- Enter the PLU code using the numeric keypad or select from the 112*2 shortcut keys.
- The scale will calculate the total price based on weight and unit price.
- Tobetsa ea PRINTA button to generate a barcode label.

Setšoantšo: Ka morao view of the Rongta RLS1100C Barcode Scale, highlighting the backlit LCD display which shows weight, unit price, and total amount.
4. Tlhokomelo
4.1 Ho hloekisa
Kamehla hloekisa sekala ka bonolo, damp cloth. Do not use abrasive cleaners, solvents, or immerse the scale in water. Ensure the weighing platter and display are free from dust and debris.
4.2 Khakanyo
While the scale is factory calibrated, periodic calibration may be required to maintain accuracy. Refer to the advanced settings menu or contact customer support for calibration procedures.
4.3 Label Printer Care
Keep the label printer mechanism clean. Remove any paper dust or adhesive residue from the print head and rollers using a soft brush or lint-free cloth. Replace label rolls promptly when empty.
5. Ho rarolla mathata
| Bothata | Lebaka le ka khonehang | Tharollo |
|---|---|---|
| Sekala ha se sebetse. | No power supply; power cable loose; power switch off. | Check power connection; ensure power switch is ON; try a different outlet. |
| Litekanyo tse fosahetseng tsa boima ba 'mele. | Scale not level; debris under platter; needs calibration. | Ensure scale is on a level surface; clean under platter; perform calibration. |
| Printer not printing labels. | No label roll; label roll incorrectly installed; print head dirty. | Install new label roll; re-install label roll correctly; clean print head. |
| Cannot connect to network/PC. | Incorrect cable; network settings incorrect; software issue. | Verify cable type (Network/RS232); check network settings; reinstall software. |
Haeba bothata bo ntse bo tsoela pele ka mor'a ho leka litharollo tsena, ka kopo ikopanye le ts'ehetso ea bareki.
6. Litlhaloso
| Sebopeho | Lintlha |
|---|---|
| Nomoro ea Mohlala | Rongta RLS1100C |
| Brand | Rongta |
| Boholo ba Boima ba Boima | 30 lik'hilograma |
| Graduation / Reading Accuracy | 5 dikgerama |
| Lebelo la ho Hatisa | 80 limilimithara / motsotsoana |
| Khokahano | Network, Serial RS232 |
| Item Storage Capacity | 10,000 lintho |
| Panel Shortcuts | 112 * 2 |
| Kenyeletso ya Matla | 100-240V / 50-60Hz |
| Thehetsoe Label Width | 30mm ho isa ho 60mm |
| Max Label Roll Diameter | 10 cm |
| Mofuta oa Pontšo | LCD e khanyang |
| Lintho tse bonahalang | Ts'epe e sa beng le mabali |
| Mmala | Silevera |
| Sebopeho sa Foromo | Letlapa la letlapa |
| Naha ea tlhaho | China |
| Libetri | 1 Betri ea lithium Ion ea hlokahala |
7. Tiisetso le Tšehetso
7.1 Boitsebiso ba Tiisetso
The Rongta RLS1100C Barcode Scale comes with a tiisetso ea lilemo tse peli covering manufacturing defects from the date of purchase. This warranty does not cover damage caused by misuse, accidents, unauthorized modifications, or normal wear and tear.
7.2 Tšehetso ea Bareki
For technical assistance, troubleshooting, or warranty claims, please contact your local distributor or the manufacturer's customer support. Please have your model number and purchase date ready when contacting support.