This manual provides essential information for the safe and proper installation, operation, and maintenance of your Veepeak 30 Amp Flanged Outlet NEMA L14-30R Locking Receptacle. Please read all instructions carefully before installation and use. Retain this manual for future reference.

Boitsebiso ba Tšireletseho

TLHOKOMELISO: Electrical shock hazard. Improper installation or use can result in serious injury or death. Always follow local electrical codes and consult a qualified electrician if you are unsure about any part of the installation process.

  • Kamehla tima motlakase ho circuit breaker kapa lebokoseng la fuse pele o kenya kapa o lokisa sesebediswa sena.
  • Ensure all wiring connections are secure and correct according to the wiring diagram and local codes.
  • O se ke wa feta ditekanyetso tse boletsweng tsa motlakase tsa sesebediswa.
  • This product is designed for use with NEMA L14-30P compatible plugs only.
  • Keep the weatherproof cap closed when the outlet is not in use to protect against moisture and dust.

Litaba tsa Sephutheloana

  • 1 x Veepeak 30 Amp NEMA L14-30R Flanged Outlet
  • Lisebelisoa tsa ho kenya

Litlhaloso

TlhalosoBoleng
Ampkhalefo30 Amps
Moqtage125/250 Volts AC
Tlhophiso ea NEMAL14-30R
Lipalo / LithapoLipalo tse 3, ho thella ha terata tse 4
Max Mojaro7500 Watts
E khothalelitsoeng Wire Gauge10 AWG/4C
Lintho tse bonahalangPolyvinyl Chloride (PVC)
SetifikeitiETL Listed (Conforms to UL & CSA standards)
E Hlokehang Hole Size2.5 inch

Ho seta le ho Kenya

Lisebelisoa li Hlokahala: Screwdriver, wire strippers, drill (for mounting hole), appropriate drill bit.

  1. Lokisetsa Sebaka sa ho Beha: Choose a suitable, dry location for installation. Drill a 2.5-inch diameter hole for the receptacle body. Ensure there is enough space behind the mounting surface for wiring connections.
  2. Lihokelo tsa Wiring:

    Refer to the wiring diagram below and the color-coded terminals on the back of the receptacle. Strip approximately 1/2 inch of insulation from each wire. Insert the wires into the corresponding terminals and tighten the screws securely. Ensure no bare wire strands are exposed outside the terminals.

    Morao view of the Veepeak L14-30R flanged outlet showing color-coded wiring terminals.

    Setšoantšo: Ka morao view of the L14-30R outlet, displaying the four color-coded terminals for wiring connections (Green for Ground, White for Neutral, Red and Black for Hot).

    NEMA L14-30R wiring diagram showing X, Y, W, G terminals for 125/250 Volt, 30 Amp kgokelo.

    Image: NEMA L14-30R configuration diagram. 'X' and 'Y' are hot lines (125V each to neutral, 250V between them), 'W' is neutral, and 'G' is ground.

    • Green (G): Terata ea fatše.
    • Bosoeu (W): Mohala o sa nke lehlakore.
    • Black (X): Hot wire (Line 1).
    • Red (Y): Hot wire (Line 2).
  3. Thabela Sekepe sa ho Apara: Insert the receptacle body into the drilled hole. Secure the flanged outlet to the mounting surface using the provided screws. Ensure it is flush and stable.
  4. Khutlisa Matla: Once installation is complete and all connections are verified, restore power at the circuit breaker.
Pele view of the Veepeak L14-30R flanged outlet with the weatherproof cap open, showing the locking receptacle.

Setšoantšo: Pele view of the Veepeak L14-30R flanged outlet with its weatherproof cap open, revealing the NEMA L14-30R locking receptacle.

Litaelo tsa Ts'ebetso

  1. Ho bula Cap: Lift the weatherproof cap to access the receptacle.
  2. Connecting a Plug: Align the NEMA L14-30P plug with the receptacle. Insert the plug and twist clockwise to lock it into place. Ensure the plug is fully seated and locked.
  3. Disconnecting a Plug: Twist the plug counter-clockwise to unlock, then pull it straight out from the receptacle.
  4. Closing the Cap: When the outlet is not in use, ensure the weatherproof cap is securely closed over the receptacle to protect it from environmental elements like rain, snow, and dust.
Pele view of the Veepeak L14-30R flanged outlet with the weatherproof cap closed, protecting the receptacle.

Setšoantšo: Pele view of the Veepeak L14-30R flanged outlet with its weatherproof cap securely closed, providing protection.

Tlhokomelo

Tlhokomelo ea kamehla e tiisa ts'ebetso e nepahetseng le polokeho.

  • Ho hloekisa: Periodically clean the exterior of the outlet with a damp cloth. Do not use abrasive cleaners or solvents. Ensure the cap is closed during cleaning.
  • Tlhahlobo: Regularly inspect the outlet for any signs of damage, wear, or corrosion. Check the weatherproof cap for proper sealing.
  • Tlhahlobo ea Khokahano: Annually, or if issues arise, disconnect power and check the wiring connections for tightness. Loose connections can cause overheating.

Ho batle phoso

  • Ha ho Matla:
    • Hlahloba sethibela-sedikadikwe kapa fuse bakeng sa potoloho. Seta botjha haeba e kgopame.
    • Netefatsa hore mohloli oa motlakase o sebetsa.
    • Ensure the plug is fully inserted and locked into the receptacle.
  • Khokahano e Lose:
    • If the plug feels loose or power is intermittent, disconnect power and inspect the wiring connections at the back of the receptacle for tightness.
    • Inspect the plug on the appliance for damage.
  • Damage to Outlet:
    • If the outlet housing or terminals show signs of damage, cracking, or burning, discontinue use immediately and replace the unit.

Haeba mehato ea ho rarolla mathata e sa rarolle bothata, buisana le setsebi sa motlakase se tšoanelehang.

Warranty le Tšehetso

Veepeak provides a one-year hassle-free replacement warranty for this product. For warranty claims or customer service inquiries, please contact Veepeak customer support through the retailer where the product was purchased or visit the official Veepeak websebaka.