1. Selelekela

The Vantec EEI 25-40/180 High-Efficiency Circulation Pump is designed to facilitate forced circulation within central heating systems. Equipped with an inverter and a processor, the pump automatically adjusts its power and pressure parameters to meet the specific demands of the system. This design ensures efficient and stable operation with minimal energy consumption.

Key operational characteristics include quiet performance, very low energy consumption (as low as 5 W), and resistance to corrosion, contributing to its durability and reliability in various heating and cooling applications.

2. Boitsebiso ba Tšireletseho

Before installation, operation, or maintenance, carefully read and understand all instructions in this manual. Failure to follow these instructions may result in property damage, injury, or death. Ensure all electrical connections are performed by a qualified electrician in accordance with local regulations. Always disconnect power before performing any service or maintenance on the pump. Do not operate the pump if it is damaged or if any electrical components are exposed to moisture.

3. Likahare tsa Sephutheloana

Netefatsa hore likarolo tsohle li teng le hore ha lia senyeha ha ho buloa:

Vantec EEI 25-40/180 pump and accessories in packaging

Image: The Vantec EEI 25-40/180 circulation pump shown with its included accessories, such as the power cable, screw fittings, and gaskets, all within its product packaging.

4. Ho seta le ho kenya

Installation of the Vantec EEI 25-40/180 pump should be carried out by qualified personnel to ensure proper function and safety. The pump is designed for integration into existing or new central heating systems.

4.1. Ho kenya Mechine

  1. Ensure the system is depressurized and drained before installation.
  2. Mount the pump in the designated location, ensuring the flow direction matches the system. The pump has a spacing of 180 mm between connections.
  3. Use the provided screw fitting kit and gaskets to connect the pump to the system piping. The connection diameter is 1 1/2" - 1". Tighten connections securely to prevent leaks.
Vantec EEI 25-40/180 pump with screw fittings attached

Image: The Vantec EEI 25-40/180 pump with its screw fittings installed, illustrating how it connects to system piping.

Included screw fitting kit and gaskets

Setšoantšo: E qaqileng view of the screw fitting kit and gaskets provided for secure and leak-proof installation.

4.2. Khokahano ea Motlakase

  1. Connect the provided power cable to the pump's electrical input.
  2. Plug the power cable into a suitable 230 V/50 Hz electrical outlet. Ensure the power supply is stable and meets the pump's requirements.
Power cable with plug for Vantec pump

Image: The power cable with a standard plug, used to connect the pump to the main electrical supply.

5. Litaelo tsa Ts'ebetso

The Vantec EEI 25-40/180 pump features an electronic control panel for easy operation and monitoring.

5.1. Initial Start-up and Auto-Adaptive Function

The pump is equipped with an auto-adaptive function, allowing it to start without requiring manual adjustments. It automatically and continuously adjusts its power to the system's needs through a permanent magnet motor and differential pressure regulator.

5.2. Electronic Control Panel

The electronic control panel is located on the top of the motor. Its digital display shows the current energy consumption in watts (W) or meters (m) of head. Use the control buttons to navigate through settings or modes if available (specific button functions are typically detailed in a separate quick start guide or on the device itself).

Close-up of Vantec EEI 25-40/180 pump control panel

Setšoantšo: Haufi view of the electronic control panel, highlighting the digital display and control buttons for monitoring and adjusting pump operation.

5.3. Applicable Systems

This circulation pump is suitable for a variety of applications, including:

6. Tlhokomelo

The Vantec EEI 25-40/180 pump is designed for minimal maintenance due to its robust construction and corrosion-resistant materials. Regular checks can help ensure optimal performance and longevity.

For any internal maintenance or repairs, it is recommended to contact a qualified service technician.

7. Ho rarolla mathata

If the pump is not operating as expected, consider the following basic checks:

For complex issues or if basic troubleshooting does not resolve the problem, contact a qualified service technician or the manufacturer's support for assistance.

8. Litlhaloso

SebopehoTlhaloso
E lekantsoe VoltageEA-230-V / 50 Hz
Tšebeliso ea Matla5 - 22 W
Sekhahla sa Phallo e Phahameng48 l/min
Max Hlooho4.5 m
Khatello e Phahameng ea Ts'ebetso10 bar
Mocheso oa ho sebetsa+2 °C ho ea +110 °C
Spacing (Port-to-Port)180 limilimithara
Bophara ba Khokahano1 1/2" - 1"
Tšireletso IndexIP44
Litekanyo (L x W x H)23 x 20 x 13 cm,
Boima ba 'mele2.35 lik'hilograma
Mokokotlo oa Motlakase100% Koporo

9. Tiisetso le Tšehetso

The Vantec EEI 25-40/180 Circulation Pump is covered by a manufacturer's warranty. Please refer to the warranty documentation provided with your purchase for specific terms and conditions. For technical support, service, or warranty claims, please contact your retailer or the Vantec customer service department. Keep your proof of purchase for warranty validation.

Litokomane tse Amanang - EEI 25-40/180

Peleview Tataiso ea ho Kenya Vantec NST-M240C4 M.2 NVMe Enclosure
Tataiso ea ho kenya mohato ka mohato bakeng sa Vantec NST-M240C4 M.2 NVMe enclosure. Ithute ho kenya NVMe SSD ea hau, ho e lokisetsa hore e sebelisoe, le ho sebetsana le lisebelisoa tse sa fetoheng.
Peleview Buka ea litaelo tsa tšebeliso ea karete ea molumo ea Vantec UGT-S100 7.1 Channel PCI
Bukana ea mosebelisi bakeng sa Karete ea Molumo ea Vantec UGT-S100 7.1 Channel PCI, likarolo tse qaqileng, litlhoko tsa sistimi, mehato ea ho kenya, likhokahano tsa 'mele, le tlhahisoleseling ea waranti.
Peleview Buka ea Basebelisi ea Vantec ALL in 1 Multifunction Internal Card Reader UGT-CR955-BK
User manual for the Vantec ALL in 1 Multifunction Internal Card Reader (Model: UGT-CR955-BK). Features include support for 59 memory card types, eSATA, USB 2.0, and FireWire ports. Installation, specifications, FAQ, and contact information.
Peleview Adaptara ea Seteishene sa ho Koka sa Vantec USB 3.0 Universal Mini Docking Station DSH-M100U3 Buka ea Mosebelisi
Bukana ea mosebelisi bakeng sa Adaptara ea Seteishene sa ho Koeketsa sa Vantec DSH-M100U3 USB 3.0 Universal Mini Docking Station. Ithute ka likarolo tsa eona, litlhoko tsa sistimi, ho kenya le ho hlophisa ponts'o bakeng sa Windows le Mac OS X.
Peleview Lipotso Tse Botsoang Khafetsa ka Vantec NexStar DX2 External Optical Drive Enclosure - NST-540S3-BK
Lipotso Tse Botsoang Khafetsa (Lipotso Tse Botsoang Khafetsa) bakeng sa Vantec NexStar DX2 external optical drive enclosure (mohlala wa NST-540S3-BK). Fumana likarabo mabapi le ho kenya, khokahano, matla, ho tsamaellana le ho rarolla mathata bakeng sa drive ea hau ea SATA optical.
Peleview Vantec CB-ISA225-U3 SATA/IDE ho USB 3.0 Adapter User Guide
Tataiso e felletseng ea adaptara ea Vantec CB-ISA225-U3, e hlalosang bokhoni ba eona, lipotso tse botsoang khafetsa, le litaelo tsa mohato ka mohato bakeng sa li-hard drive tsa SATA le IDE.