PRIOS 9917033

PRIOS Edwina LED Ceiling Light Instruction Manual

Mohlala: 9917033

Selelekela

Thank you for choosing the PRIOS Edwina LED Ceiling Light. This manual provides important information regarding the safe installation, operation, and maintenance of your new lighting fixture. Please read these instructions carefully before installation and retain them for future reference.

The Edwina LED Ceiling Light is designed for indoor use, including bathrooms and damp rooms, thanks to its IP44 protection rating. It features an integrated LED light source with adjustable color temperature and is compatible with external dimmers for brightness control.

Litaelo tsa Tšireletseho

Litaba tsa Sephutheloana

Please check that all components are present and undamaged before installation:

Ho seta le ho Kenya

Bohlokoa: Ensure the main power supply is switched off before installation.

  1. Itokisetse ho Kenya: Turn off the electricity at the main circuit breaker. Use a voltage tester ho netefatsa hore motlakase o timme.
  2. Remove Mounting Bracket: Carefully detach the mounting bracket from the back of the light fixture.
  3. Lintlha tsa ho Drilling Mark: Hold the mounting bracket against the ceiling at the desired installation location. Mark the positions for drilling holes.
  4. Drill Holes and Insert Wall Plugs: Drill holes at the marked positions and insert appropriate wall plugs (if required for your ceiling type).
  5. Secure Mounting Bracket: Attach the mounting bracket to the ceiling using the provided screws.
  6. Adjust Color Temperature (DIP Switch): Before connecting the wires and mounting the fixture, locate the DIP switch on the back of the LED driver. This switch allows you to select the desired color temperature: 3000K (Warm White), 4000K (Neutral White), or 6000K (Cool White). Select your preferred setting.
Close-up of the PRIOS Edwina LED Ceiling Light's internal wiring and DIP switch for color temperature selection.

Setšoantšo: Ka hare view showing the DIP switch for color temperature selection (3000K, 4000K, 6000K).

  1. Khokelo ea Mohala: Connect the household electrical wires to the terminals on the fixture's driver. Ensure correct polarity (Live, Neutral, Earth) according to local regulations. Secure all connections.
Ka hare view of the PRIOS Edwina LED Ceiling Light showing wiring terminals and mounting points.

Image: Internal wiring and mounting mechanism of the ceiling light.

  1. Mount the Fixture: Carefully align the light fixture with the mounting bracket and secure it in place. Ensure it is firmly attached to the ceiling.
  2. Khutlisa Matla: Hang ha ts'ebetso e phethiloe 'me likhokahano tsohle li sireletsehile, khutlisetsa matla ho sekhechana se seholo sa potoloho.

Litaelo tsa Ts'ebetso

The PRIOS Edwina LED Ceiling Light is designed for simple operation.

Four images showing the PRIOS Edwina LED Ceiling Light illuminated at different color temperatures: warm white, neutral white, and cool white, and off.

Image: The Edwina LED Ceiling Light displaying various color temperatures.

Tlhokomelo

The PRIOS Edwina LED Ceiling Light requires minimal maintenance.

Ho batle phoso

If you encounter issues with your PRIOS Edwina LED Ceiling Light, please refer to the following common problems and solutions:

BothataLebaka le ka khonehangTharollo
Leseli ha le khanye.Ha ho phepelo ea motlakase.
Khokahano ea wiring e hlephileng.
Sesepa sa lebota se nang le phoso.
Sheba sekhechana sa potoloho le switch ea lebota.
Ensure power is off, then check wiring connections.
Test the wall switch.
Ho panyapanya ha leseli.Khokahano ea wiring e hlephileng.
Sebopeho sa dimmer se sa lumellaneng.
Ensure power is off, then check wiring connections.
Ensure your dimmer is compatible with LED lighting.
Mocheso o fosahetseng oa 'mala.DIP switch set incorrectly.Disconnect power, remove fixture, adjust DIP switch to desired setting, then re-install.

Haeba bothata bo ntse bo tsoela pele ka mor'a ho leka litharollo tsena, ka kopo ikopanye le ts'ehetso ea bareki.

Litlhaloso

Detailed technical specifications for the PRIOS Edwina LED Ceiling Light (Model 9917033):

SebopehoTlhaloso
Nomoro ea Mohlala9917033
BrandPRIOS
Lintho tse bonahalangPolycarbonate, Aluminum
MmalaSilver, White
Litekanyo (L x W x H)12.2 cm x 12.2 cm x 3.5 cm
Boima ba 'mele173 g
Mohloli oa LeseliLED e kopantsoeng
Nomoro ea Lamps1
Wattage6 W
Moqtage230 V AC
Flux e khanyang360 Lumen
Mocheso oa Mobala3000K, 4000K, 6000K (selectable via DIP switch)
Ho fifalaYes (with external LED-compatible dimmer)
Karolelano ea Nako ea BopheloLihora tse 25,000
Tekanyetso ea Tšireletso ea IPIP44
Sehlopha sa TšireletsoII
Sehlopha sa Matla a MatlaF
Tšebeliso e khethehilengCeiling, Hall, Bathroom (Indoor)
Diagram showing the dimensions of the PRIOS Edwina LED Ceiling Light: 122mm diameter and 35mm height.

Image: Product dimensions (Diameter 122mm, Height 35mm).

EU Energy Label for Prios L9001974, showing energy efficiency class F and 6 kWh/1000h consumption.

Image: EU Energy Label for the fixture, indicating class F. For more details, scan the QR code or visit eprel.ec.europa.eu/qr/745143.

Warranty le Tšehetso

For warranty information or technical support, please refer to the purchase documentation or contact the seller directly through your Amazon account. Keep your proof of purchase for any warranty claims.

Litokomane tse Amanang - 9917033

Peleview PRIOS 2621002 LED Outdoor Wall Light - Technical Data and Installation
Comprehensive technical specifications and installation guide for the PRIOS 2621002 LED outdoor wall light, detailing its features, usage, safety, and assembly.
Peleview Prios L9001205 LED Light Source - Product Information Sheet
Detailed product information sheet for the Prios L9001205 LED light source, including energy efficiency, luminous flux, color temperature, power consumption, dimensions, and spectral distribution data. Compliant with EU Regulation 2019/2015.
Peleview Manuale d'Uso e Installazione Ariston PRIOS R32 Climatizzatore d'Aria
Guida completa all'uso e all'installazione del climatizzatore Ariston PRIOS R32. Include istruzioni di sicurezza, procedure di montaggio, funzionamento e manutenzione.
Peleview Ariston Air Conditioning Units 2018: PROtech Range, R32 Refrigerant, Smart Features
Explore the Ariston PROtech Professional Range of air conditioning units for 2018, featuring R32 refrigerant, energy efficiency (ErP), smart climate control with the Ariston Clima app, and detailed technical specifications. Includes KIOS, ALYS R32, PRIOS R32, and DEHUMIDIFIERS.