Fieldpiece VP87

Fieldpiece VP87 Vacuum Pump Instruction Manual

Mohlala: VP87

Letšoao: Mosebetsi oa tšimo

Selelekela

The Fieldpiece VP87 Vacuum Pump is a professional-grade HVAC tool designed for efficient and reliable system evacuation. Featuring an 8 CFM flow rate and a powerful 3/4 HP DC motor, it is built for both residential and commercial applications. Its innovative RunQuick Oil Change System simplifies maintenance, allowing for quick and mess-free oil changes without interrupting the vacuum process. The VP87 is also A2L compatible, making it suitable for use with modern refrigerants.

Fieldpiece VP87 Vacuum Pump

Image: The Fieldpiece VP87 Vacuum Pump, a robust yellow and black unit with clear oil reservoirs and multiple ports.

Lintlha tsa Bohlokoa le Melemo

Fieldpiece VP87 Features and Benefits

Image: A graphic highlighting the key features and benefits of the Fieldpiece VP87 Vacuum Pump, including its fast evacuation, reliable power, and RunQuick Oil Change System.

Se Kenyellelitsoeng

Upon unpacking your Fieldpiece VP87 Vacuum Pump, please verify that all components are present:

Fieldpiece VP87 What's Included

Image: A visual representation of the Fieldpiece VP87 Vacuum Pump and its included accessories: the pump unit, two bottles of vacuum pump oil, and the power cord.

Tlhophiso

  1. Initial Oil Fill: Before first use, ensure the oil reservoir is filled to the MAX line using the provided Fieldpiece vacuum pump oil. Unscrew the large black cap on top of the unit and carefully pour the oil into the reservoir. The clear sight glass allows you to monitor the oil level.
  2. Khokelo ea Matla: Connect the power cord to the designated port on the side of the vacuum pump. Ensure the connection is secure to prevent accidental disconnection during operation.
  3. Khokahano ea Hose: The VP87 features four inline ports for hose management: 1/4", 1/2", and two 3/8" ports. Connect your vacuum hoses to the appropriate ports on the pump and to the system being evacuated. Ensure all connections are tight to prevent leaks.

Litaelo tsa Ts'ebetso

  1. Matlafatsa: Flip the power switch to the 'ON' position. The pump will begin operation.
  2. Khase Ballast Valve: For initial pull-down, it is recommended to open the gas ballast valve (located on the side of the unit) to help remove moisture and speed up the process. Once the vacuum reaches approximately 3000 microns, close the gas ballast valve for a deeper vacuum.
  3. Monitoring Vacuum: Use a micron gauge (not included) to monitor the vacuum level of the system. Continue operation until the desired vacuum level is achieved.
  4. RunQuick Oil Change System: This system allows for oil changes without shutting down the pump or losing vacuum.
    • To drain old oil: While the pump is running, open the valve on the left oil reservoir. The old oil will drain into the empty container.
    • To add new oil: Close the drain valve. Remove the black cap on top of the unit and pour new Fieldpiece vacuum pump oil into the reservoir until the level is between the MIN and MAX lines in the sight glass.
  5. Exhaust Port: A garden hose can be connected to the exhaust port on the side of the unit to direct exhaust away from the work area.

Video: An official Fieldpiece video providing an overview of the Fieldpiece Vacuum Pumps, highlighting their power, stability, multiple ports, and the convenient RunQuick Oil Change System. It also mentions A2L compatibility.

Tlhokomelo

Regular maintenance ensures the longevity and optimal performance of your Fieldpiece VP87 Vacuum Pump.

Ho batle phoso

If you encounter issues with your VP87 Vacuum Pump, refer to the following common troubleshooting steps:

For issues not covered here, please contact Fieldpiece customer support.

Litlhaloso

TšobotsiBoleng
Sekhahla sa Phallo8 CFM
Bokhoni ba Oli8oz (237mL)
Oil CompatibilityFieldpiece Vacuum Pump Oil (E hloekisitsoeng haholo le e ntlafalitsoeng bakeng sa ho tiisa le ho tlotsa hantle)
Drain ea oliBalofo ea bolo
Boholo ba Port(1) 1/4", (2) 3/8", (1) 1/2"
SekontiriRotary vane, tse peli stage
Motor3/4 HP Brushless DC
RPM2500
Mohloli oa Matla120 VAC @ 60 Hz 1 mohato
Tharollo ea Hona Joale ka Lebitso6.0 AAC
Ultimate Vacuum at Input Ports15 microns
Litekanyo19.72"L x 11.65"W x 15.98"H (201 mm x 296 mm x 406 mm)
Boima ba 'mele27 lb / 12.4 lik'hilograma
Tikoloho ya Tshebetso30°F ho isa ho 122°F (-1.1°C ho isa ho 50°C)
Fieldpiece VP87 Specifications Table

Image: A detailed table outlining the technical specifications of the Fieldpiece VP87 Vacuum Pump, including flow rate, oil capacity, motor type, and dimensions.

Boitsebiso ba Warranty

For detailed warranty information regarding your Fieldpiece VP87 Vacuum Pump, please refer to the official Fieldpiece website or the warranty card included with your product. Warranty terms and conditions may vary.

Tšehetso

If you require further assistance or have questions about your Fieldpiece VP87 Vacuum Pump, please contact Fieldpiece customer support:

Litokomane tse Amanang - VP87

Peleview Fieldpiece Vacuum Pump with RunQuick™ Oil Change System Operator's Manual
Operator's manual for Fieldpiece VPX7, VP87, and VP67 vacuum pumps with RunQuick™ Oil Change System. Covers operation, safety, maintenance, and troubleshooting for professional HVAC/refrigeration use.
Peleview Buka ea Mosebetsi ea Fieldpiece VP55/VP85 Vacuum Pump - Sistimi ea Phetoho ea Oli ea RunQuick
Bukana ea tataiso ea mosebelisi bakeng sa lipompo tsa vacuum tsa Fieldpiece VP55 le VP85 tse nang le Sistimi ea RunQuick™ Oil Change System. E akaretsa ts'ebetso, tlhokomelo, polokeho, ho rarolla mathata le litlhaloso bakeng sa litsebi tsa HVAC/R.
Peleview Fieldpiece SMAN® Kältemittelverteiler mit integriertem Unterdruckmessgerät: Bedienungsanleitung
Umfassende Bedienungsanleitung für die Fieldpiece SMAN® Kältemittelverteiler Modelle SM382VINT und SM482VINT mit integriertem Unterdruckmessgerät. Enthält Informationen zu Installation, Betrieb, Wartung und technischen Daten.
Peleview Fieldpiece SMAN Kølemiddelmanifold Brugsvejledning | SM382VINT SM482VINT
Denne brugsvejledning giver detaljeret information om Fieldpiece SMAN® kølemiddelmanifolden med indbygget vakuummåler. Dækker funktioner, drift, vedligeholdelse og specifikationer for modellerne SM382VINT og SM482VINT, designet til HVACR-professionelle.
Peleview Fieldpiece SM480V SMAN Refrigerant Manifold + Micron Gauge Operator's Manual
Operator's manual for the Fieldpiece SM480V SMAN Refrigerant Manifold + Micron Gauge (4 Port). This guide covers features, operation, maintenance, and specifications for this professional HVAC tool.
Peleview Fieldpiece JL3PR Job Link System Pressure Probe Operator's Manual
Operator's manual for the Fieldpiece JL3PR Job Link System Pressure Probe, including quick start guide, description, maintenance, specifications, operation, limited warranty, and obtaining service information.