The Tektronix TBS2000B series digital oscilloscopes are designed to provide high-level signal display and measurement, which are critical functions for any oscilloscope. The TBS2074B model, with its 70MHz bandwidth and 4 channels, offers an intuitive user experience and powerful analysis capabilities. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your TBS2074B oscilloscope.

Tektronix TBS2074B Digital Oscilloscope front view

Setšoantšo sa 1.1: Pele view of the Tektronix TBS2074B Digital Oscilloscope.

2. Likarolo tsa Bohlokoa

The TBS2074B oscilloscope is equipped with features designed to enhance usability and measurement accuracy:

3. Seta

3.1 Ho phutha

Carefully remove the oscilloscope and all accessories from the packaging. Verify that all components listed in the packing list are present and undamaged. Retain the original packaging for future transport or storage.

3.2 Matla a ho Hokela

Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable power outlet. Ensure the power source meets the voltage and frequency requirements specified on the device label.

Ka morao view of Tektronix TBS2074B showing power input and connectivity ports

Figure 3.1: Rear panel of the oscilloscope with power input and connectivity ports.

3.3 Matla a Pele a Buletsoe

Press the power button located on the front panel. The oscilloscope will perform a self-test and then display the main waveform screen. Allow a few moments for the system to fully initialize.

4. Ts'ebetso

4.1 Sehokelo sa Mosebelisi Overview

The TBS2074B features a large 9-inch display and an intuitive front panel with dedicated controls for vertical, horizontal, and trigger settings. Navigation buttons and a rotary knob allow for easy menu access and parameter adjustment.

Tektronix TBS2074B display showing 15 horizontal divisions

Figure 4.1: The oscilloscope display highlighting the 15 horizontal divisions for extended signal view.

4.2 Litekanyo tsa Motheo

To perform a basic measurement:

  1. Connect the appropriate probe to one of the input channels (CH1-CH4) on the front panel.
  2. Connect the probe tip to the circuit point you wish to measure.
  3. Adjust the vertical scale (Volts/Div) and horizontal scale (Sec/Div) knobs to display the waveform clearly.
  4. Use the Trigger controls to stabilize the waveform on the screen.
  5. Press the 'Measure' button to access automatic measurement options.
Tektronix TBS2074B with probes connected to input channels

Figure 4.2: Connecting probes to the oscilloscope input channels.

4.3 Mesebetsi e tsoetseng pele

The TBS2074B offers advanced analysis tools:

Tektronix TBS2074B display showing automatic measurement menu

Figure 4.3: The automatic measurement selection menu on the oscilloscope display.

Tektronix TBS2074B display showing waveform with search and mark function in use

Figure 4.4: Waveform display demonstrating the search and mark function.

5. Khokahano

The TBS2074B offers various connectivity options for data transfer and remote control:

Close-up of the rear panel of Tektronix TBS2074B showing USB and Ethernet ports

Setšoantšo sa 5.1: Haufi view of the rear panel connectivity ports.

Tektronix TBS2074B connected to a laptop via USB cable

Figure 5.2: The oscilloscope connected to a laptop for data transfer or remote control.

6. Tlhokomelo

6.1 Ho hloekisa

To maintain the performance and appearance of your oscilloscope, regularly clean the exterior surfaces. Use a soft, damp cloth with a mild detergent. Avoid abrasive cleaners or solvents that could damage the plastic components or display.

6.2 Polokelo

When not in use, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. If storing for extended periods, it is recommended to use the original packaging or a protective case.

7. Ho rarolla mathata

This section provides solutions to common issues you might encounter with your TBS2074B oscilloscope.

BothataLebaka le ka khonehangTharollo
Ha ho matlaPower cord not connected; Power outlet fault; Internal fuse blownCheck power cord connection; Test power outlet; Contact service for fuse replacement
Ha ho na waveform e hlahangProbe not connected; Incorrect vertical/horizontal settings; Trigger not set correctlyEnsure probe is connected; Adjust Volts/Div and Sec/Div; Adjust trigger level or mode
Sebopeho se sa tsitsang sa maqhubuIncorrect trigger source or level; Signal noiseVerify trigger source and adjust trigger level; Use averaging or bandwidth limit to reduce noise

If you encounter issues not covered here, or if the suggested solutions do not resolve the problem, please contact Tektronix customer support.

8. Litlhaloso

Detailed technical specifications for the Tektronix TBS2074B Digital Oscilloscope:

TlhalosoBoleng
MoetsiTektronix
Nomoro ea MohlalaTBS2074B
Bophahamo ba motlakase70 MHz (Upgradeable to 200 MHz with option)
Mecha ea Analog4
Max Sample Rate2 GS/s (half channel), 1 GS/s (all channels)
Rekota Bolelele5 M points
Pontšo9-inch WVGA Color Display
Automatic Measurements32 mefuta
Probe InterfaceTekVPI
KhokahanoUSB 2.0 Host (front), USB 2.0 Device (rear), 10/100BASE-T Ethernet, Wi-Fi
Boima ba Ntho3 lik'hilograma
Litekanyo tsa sephutheloana50 x 40 x 26 cm,
Kenyellelitsoe LikaroloanaStandard Accessory KIT
Batteries UsedChe
Letsatsi la Pele la ho Fumaneha (Amazon.co.jp)2020/5/11

9. Tiisetso le Tšehetso

Tektronix products are designed for reliability and performance. For information regarding warranty coverage, technical support, and service, please refer to the official Tektronix website or contact your local Tektronix representative. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, visit the official Tektronix support page: www.tek.com/support

Litokomane tse Amanang - TBS2074B

Peleview Tektronix 7 Series DPO Performance Oscilloscope DPO714AX Help Guide
Comprehensive help guide for the Tektronix 7 Series DPO Performance Oscilloscope, model DPO714AX. Learn about features, operation, configuration, and troubleshooting for this advanced test and measurement instrument.
Peleview Buka ea litaelo ea Tektronix 7L12 Spectrum Analyzer
This document provides comprehensive instructions for operating, testing, calibrating, and servicing the Tektronix 7L12 Spectrum Analyzer, a dual-width plug-in unit for 7000-Series Oscilloscopes. It details specifications, front panel controls, operational procedures, calibration methods, and applications for RF signal analysis.
Peleview Tektronix 5 Series B MSO: Litlhaloso le Netefatso ea Ts'ebetso
Litlhaloso tse qaqileng le mekhoa ea netefatso ea ts'ebetso bakeng sa li-oscilloscope tsa Tektronix 5 Series B MSO, ho kenyeletsoa le mehlala ea MS054B, MS056B, le MS058B. Lintlha tsa bohlokoa tsa tekheniki bakeng sa baenjiniere le litsebi.
Peleview Buka ea Tšebeletso ea Tektronix 2235 Oscilloscope
Bukana ea litšebeletso tse pharalletseng bakeng sa Tektronix 2235 Oscilloscope. E kenyelletsa lintlha tse qaqileng, litaelo tsa ts'ebetso, khopolo ea ts'ebetso, tlhahlobo ea ts'ebetso, mekhoa ea ho lokisa, tlhokomelo, tharollo ea mathata, le manane a likarolo bakeng sa basebeletsi ba nang le tsebo.
Peleview Tektronix 3 Series Mixed Domain Oscilloscope Help (MD032, MD034)
Tataiso ea mosebelisi bakeng sa Tektronix 3 Series Mixed Domain Oscilloscope (MD032, MD034), lintlha tse qaqileng, ts'ebetso, tlhophiso, le tharollo ea mathata bakeng sa sesebelisoa sena se tsoetseng pele sa teko le tekanyo.
Peleview Tektronix 3 Series MDO Oscilloscope MD032 & MD034: Specifications and Performance Verification
Detailed specifications and performance verification procedures for the Tektronix 3 Series Mixed Domain Oscilloscopes (MDO32 and MDO34), covering analog and digital channel performance, acquisition systems, trigger capabilities, and more.