1. Selelekela
This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of the Danfoss 077B6827 Temperature Control. This digital, wired temperature controller is designed for precise temperature regulation in various applications. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Boitsebiso ba Tšireletseho
- Kotsi ea Motlakase: Installation and servicing must be performed by qualified personnel only. Disconnect all power to the unit before performing any work.
- Tšebeliso e nepahetseng: Use this device only for its intended purpose as a temperature control. Any other use may result in damage or injury.
- Maemo a Tikoloho: Ensure the operating environment is within the specified temperature and humidity ranges to prevent malfunction.
- Karolo ea Botšepehi: Do not operate the device if any components appear damaged.
3. Sehlahisoa Overview
The Danfoss 077B6827 is a robust temperature control unit featuring a rotary knob for manual adjustments and digital connectivity for advanced control. It includes a main control module and a capillary tube sensor for accurate temperature measurement.

- Setsi sa Taolo: The main body housing the electrical components and the rotary control knob.
- Lekhoba la Rotary: Used for setting the desired temperature or operational mode.
- Capillary Tube Sensor: A thin metallic tube containing a temperature-sensitive fluid, used to detect ambient or process temperature.
- Litheminale tsa Wiring: Located on the control unit for electrical connections.
4. Ho seta le ho kenya
Ho kenya ho lokela ho etsoa ke setsebi se tšoanelehang.
- Ho Khaoha ha Motlakase: Ensure the main power supply to the equipment where the control will be installed is completely disconnected.
- Ho hlongoa: Mount the control unit in a suitable location, typically a wall mount, ensuring it is secure and accessible for adjustments. Refer to the included mounting hardware and instructions.
- Wiring: Connect the control unit to the electrical system using the provided wiring harness. Follow the wiring diagram specific to your application. This is a wired connectivity device.
- Sebaka sa Sensor: Position the capillary tube sensor in the area where temperature is to be measured. Ensure the sensor is not kinked or damaged and is free from external heat sources or drafts that could affect accuracy.
- Kenya Betri: As this unit is battery-powered, install the required batteries according to the polarity markings.
- Khokelo ea Matla: Once all connections are secure and verified, restore power to the system.
5. Litaelo tsa Ts'ebetso
The Danfoss 077B6827 offers both manual and digital control options.
- Manual Setting ea Mocheso: Use the rotary knob on the front of the unit to select the desired temperature or operational setting. The knob typically features numerical indicators (e.g., 0-8) corresponding to different temperature ranges or control levels.
- Pontšo ea Dijiti: The unit features a digital display for clear indication of current settings or measured temperature.
- Taolo ea App: For advanced control and monitoring, the device supports app control. Refer to the specific Danfoss app documentation for pairing and usage instructions.
- BACnet MS/TP Connectivity: This controller can be integrated into Building Management Systems (BMS) via BACnet MS/TP protocol for centralized control and data exchange. Consult your BMS administrator for integration details.
6. Tlhokomelo
- Ho hloekisa: Periodically clean the exterior of the control unit with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the unit.
- Phetoho ea Betri: When the battery indicator signals low power, replace the batteries promptly to ensure continuous operation. Refer to the battery compartment for correct battery type and polarity.
- Tlhahlobo ea Sensor: Regularly inspect the capillary tube sensor for any signs of damage, kinks, or corrosion. Ensure it remains securely positioned.
- Tlhahlobo ea Litsebi: It is recommended to have the system professionally checked annually to ensure optimal performance and calibration.
7. Ho rarolla mathata
If you encounter issues, perform the following basic checks before contacting support.
- No Power/Unit Not Responding:
- Check if the main power supply to the system is active.
- Verify that the batteries are correctly installed and not depleted. Replace if necessary.
- Inspect all wiring connections for looseness or damage.
- Lipalo tse Fosahetseng tsa Mocheso:
- Ensure the capillary tube sensor is correctly positioned and not obstructed.
- Check for any physical damage to the sensor tube.
- Verify that the sensor is not exposed to unintended heat sources or drafts.
- Control Not Adjusting Temperature:
- Confirm the rotary knob is set to the desired position.
- If using app control, ensure the app is connected and sending commands correctly.
- Check for any error messages on the digital display or within the app.
If problems persist after performing these checks, contact Danfoss technical support.
8. Litlhaloso
| Sebopeho | Lintlha |
|---|---|
| Brand | Lerato |
| Nomoro ea Mohlala | 077B6827 (Item model number: 46-1387) |
| Mofuta oa Molaoli | Rotary Knob / Push Button |
| Mmala | Ntsho |
| Tšebeliso e khethehileng | Taolo ea Mocheso |
| Mofuta oa Taolo ea Mocheso | Dijithale |
| Theknoloji ea Khokahano | Tse thapo |
| Kenyellelitsoe Likaroloana | 1 x Thermostat, 1 x Wiring Harness |
| Mohloli oa Matla | Matla a Battery |
| Boima ba Ntho | 6.7 lik'hilograma |
| Mofuta oa Pontšo | Dijithale |
| Mokhoa oa ho Laola | App, Rotary Knob |
| Khokahano Protocol | BACnet MS / TP |
| Mofuta oa ho Beha | Thaba ea Lerako |
| Backlight | Che |
| UPC | 254613875887 |
9. Tiisetso le Tšehetso
For information regarding product warranty, technical support, or service, please refer to the official Danfoss website or contact your local Danfoss distributor. You can also visit the Danfoss Store on Amazon bakeng sa lintlha tse ling tsa sehlahisoa.