1. Selelekela
This manual provides detailed instructions for the safe and effective use of your Sealey MM20HV Digital Multimeter. The MM20HV is a heavy-duty, general-purpose multimeter designed for various electrical measurements, featuring a clear LCD display, data hold function, temperature probe, and diode test facility. It is housed in a rugged rubber boot with an integral stand for durability and convenience.
Ka kopo bala bukana ena ka botlalo pele o sebedisa sesebediswa mme o se boloke bakeng sa tshebediso ya sona nakong e tlang.
2. Boitsebiso ba Tšireletseho
Always observe basic safety precautions when using electrical testing equipment to reduce the risk of fire, electric shock, and personal injury.
- Bala Litaelo: Understand all operating instructions and safety warnings before use.
- Hlahloba Sesebediswa: Before each use, inspect the multimeter and test leads for any damage. Do not use if damaged.
- Proper Range: Always select the correct function and range for the measurement.
- Moqtage Meeli: Do not exceed the maximum input limits specified for each range.
- Live Circuits: Never measure resistance, continuity, or diode on a live circuit. Ensure power is off and circuits are discharged.
- Insulation: Keep fingers behind the probe barriers during measurements.
- Tikoloho: Do not use the multimeter in wet conditions or in the presence of explosive gases or fumes.
- Litšebeletso: Refer all servicing to qualified personnel. Battery and fuse replacement are the only user-serviceable parts.
3. Se ka Lebokoseng
Upon unpacking, ensure all items listed below are present and undamaged:
- Sealey MM20HV Digital Multimeter
- Melato ea Teko (Bokhubelu le Botšo)
- Thermocouple (Temperature Probe)
- Bukana ea mosebelisi (tokomane ena)

Setšoantšo sa 1: Sealey MM20HV Digital Multimeter shown with included test leads and thermocouple.
4. Seta
4.1. Ho kenya Battery
The Sealey MM20HV requires two AAA batteries for operation.
- Fumana sekoahelo sa karolo ea betri ka morao ho multimeter.
- Sebelisa screwdriver ho tlosa screw e tiisang sekoahelo.
- Kenya libeteri tse peli tsa AAA, u shebe polarity e nepahetseng (+ le -) joalo ka ha ho bontšitsoe ka har'a karoloana.
- Tlosa sekoaelo sa karolo ea betri 'me u se sireletse ka screw.
4.2. Baetapele ba Liteko ba Hokelang
Proper connection of test leads is essential for accurate and safe measurements.
- Insert the black test lead into the "COM" (Common) jack.
- Bakeng sa boholo ba voltage, resistance, and continuity measurements, insert the red test lead into the "VΩmA" jack.
- For high current (up to 10A DC) measurements, insert the red test lead into the "10A DC" jack. Ensure the function dial is set to the appropriate current range.

Setšoantšo sa 2: Multimeter with black lead in COM and red lead in VΩmA jack.
5. Litaelo tsa Ts'ebetso
The Sealey MM20HV offers 8 functions for various electrical measurements.
5.1. Matla On/O tima
Rotate the central function dial from the "OFF" position to any desired measurement function to turn the multimeter on. To turn off, rotate the dial back to "OFF".
5.2. Measuring DC Voltage (V=)
- Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
- Set the function dial to the desired DC Voltage range (e.g., 200mV, 2V, 20V, 200V, 600V). If the voltage is unknown, start with the highest range and decrease as necessary.
- Connect the test probes across the component or circuit to be measured.
- Bala voltage bohlokoa ponts'ong ea LCD.
5.3. Ho lekanya AC Moqtage (V~)
- Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
- Set the function dial to the desired AC Voltagmefuta e fapaneng (mohlala, 200V, 600V).
- Connect the test probes across the AC voltage mohloli.
- Bala voltage bohlokoa ponts'ong ea LCD.
5.4. Measuring DC Current (A=)
Tlhokomeliso: Never connect the multimeter in parallel with a voltage source when measuring current. Always connect in series with the load.
- Insert the black lead into the "COM" jack.
- For currents up to 200mA, insert the red lead into the "VΩmA" jack. For currents up to 10A, insert the red lead into the "10A DC" jack.
- Set the function dial to the appropriate DC Current range (e.g., 2mA, 20mA, 200mA, 10A).
- Bula potoloho moo hona joale ho lokelang ho lekanngoa teng 'me u hokahanye multimeter ka tatellano.
- Bala boleng ba hajoale ponts'ong ea LCD.
5.5. Measuring Resistance (Ω)
Tlhokomeliso: Netefatsa hore potoloho e felisitsoe matla 'me li-capacitor tsohle lia ntšoa pele ho lekanyetsoa khanyetso.
- Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
- Set the function dial to the desired Resistance range (e.g., 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ).
- Connect the test probes across the component whose resistance is to be measured.
- Bala boleng ba khanyetso ponts'ong ea LCD.
5.6. Teko ea Tsoelo-pele e Utloahalang
This function allows for quick checks of circuit continuity with an audible tone.
- Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
- Set the function dial to the continuity symbol (often shared with diode test).
- Connect the test probes across the circuit or component.
- An audible tone indicates continuity (low resistance). The display will show the resistance value.
5.7. Diode/Transistor Verification
This function allows for testing diodes and transistors.
- Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
- Set the function dial to the diode symbol.
- For diode testing, connect the red probe to the anode and the black probe to the cathode. The display will show the forward voltage drop. Reverse the probes; the display should show "OL" (Open Loop) for a good diode.
- For transistor (hFE) testing, insert the transistor leads into the appropriate NPN or PNP sockets on the multimeter. The display will show the hFE value.
5.8. Measuring Temperature (°C)
The multimeter includes a thermocouple for temperature measurements.
- Remove the test leads from the input jacks.
- Insert the thermocouple plug into the "VΩmA" and "COM" jacks, observing polarity if indicated.
- Set the function dial to the "°C" range.
- Place the tip of the thermocouple on or near the object whose temperature is to be measured.
- Read the temperature value in Celsius on the LCD display.
5.9. Mosebetsi oa ho Tšoara Lintlha
Press the "HOLD" button (typically a green button on the front panel) to freeze the current reading on the display. Press it again to release the hold and resume live readings.
6. Tlhokomelo
6.1. Ho hloekisa
Hlakola nyeoe ka papatsoamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is off and disconnected from any circuits before cleaning.
6.2. Phetoho ea Battery
When the battery indicator appears on the display, replace the batteries as described in Section 4.1. Always use fresh AAA batteries.
6.3. Fuse Replacement
If the current measurement function stops working, the fuse may need replacement.
- Ensure the multimeter is turned off and all test leads are disconnected.
- Remove the battery compartment cover and batteries.
- Locate the fuse(s) inside the compartment. The MM20HV typically uses a 200mA/250V fast-blow fuse for the mA range and a 10A/250V fast-blow fuse for the 10A range.
- Carefully remove the old fuse and replace it with a new fuse of the exact same type and rating.
- Replace the batteries and battery compartment cover.
Bohlokoa: Never use a fuse with a different rating or bypass a fuse. This can damage the multimeter and pose a serious safety hazard.
7. Ho rarolla mathata
| Bothata | Lebaka le ka khonehang | Tharollo |
|---|---|---|
| Ha ho pontsho kapa pontsho e lefifi | Libetri tse shoeleng kapa tse tlase | Replace batteries (Section 4.1) |
| Litemana tse fosahetseng | Incorrect range selected, poor lead connection, damaged leads | Select appropriate range, ensure leads are fully inserted, inspect leads for damage and replace if necessary |
| Tekanyo ea hajoale ha e sebetse | Fuse e phatlohileng | Replace fuse (Section 6.3) |
| "OL" (Ho jara ho feta tekano) ho bontshitswe | Measurement exceeds selected range, open circuit (for resistance/continuity) | Select a higher range, check circuit for breaks |
8. Litlhaloso
The following table outlines the technical specifications for the Sealey MM20HV Digital Multimeter.
| Tlhaloso | Boleng |
|---|---|
| Mohlala No. | MM20HV |
| Brand | Sealey |
| Mesebetsi | 8 (AC/DC Voltage, DC Current, Resistance, Temperature, Audible Continuity, Diode/Transistor Verification) |
| Mofuta oa AC Voltage (Accuracy) | 200V, 600V (±2%) |
| DC Moqtage (Accuracy) | 200mV, 2V, 20V, 200V, 600V (±0.5% to ±0.8%) |
| DC Current (Accuracy) | 2mA, 20mA, 200mA, 10A (±1% to ±2%) |
| Resistance (Accuracy) | 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ (±0.8% to ±1%) |
| Mocheso Range | Up to 1000°C (with thermocouple) |
| Mohloli oa Matla | 2 x AAA Batteries |
| Boima ba Ntho | 0.29 Lik'hilograma (hoo e ka bang li-ounces tse 10.2) |
| Litekanyo (L x W x H) | 1.97 x 4.33 x 6.18 lisenthimithara |
| Maemo a Tšireletseho | IEC 1010 |
Tlhokomeliso: Litlhaloso li ka fetoha ntle le tsebiso.
9. Tiisetso le Tšehetso
For information regarding warranty coverage, technical support, or service, please refer to the warranty card included with your product or contact Sealey customer service directly. Contact details are typically available on the manufacturer's official websebaka.