This manual provides detailed instructions for the safe and effective use of your Sealey MM20HV Digital Multimeter. The MM20HV is a heavy-duty, general-purpose multimeter designed for various electrical measurements, featuring a clear LCD display, data hold function, temperature probe, and diode test facility. It is housed in a rugged rubber boot with an integral stand for durability and convenience.

Ka kopo bala bukana ena ka botlalo pele o sebedisa sesebediswa mme o se boloke bakeng sa tshebediso ya sona nakong e tlang.

2. Boitsebiso ba Tšireletseho

Always observe basic safety precautions when using electrical testing equipment to reduce the risk of fire, electric shock, and personal injury.

  • Bala Litaelo: Understand all operating instructions and safety warnings before use.
  • Hlahloba Sesebediswa: Before each use, inspect the multimeter and test leads for any damage. Do not use if damaged.
  • Proper Range: Always select the correct function and range for the measurement.
  • Moqtage Meeli: Do not exceed the maximum input limits specified for each range.
  • Live Circuits: Never measure resistance, continuity, or diode on a live circuit. Ensure power is off and circuits are discharged.
  • Insulation: Keep fingers behind the probe barriers during measurements.
  • Tikoloho: Do not use the multimeter in wet conditions or in the presence of explosive gases or fumes.
  • Litšebeletso: Refer all servicing to qualified personnel. Battery and fuse replacement are the only user-serviceable parts.

3. Se ka Lebokoseng

Upon unpacking, ensure all items listed below are present and undamaged:

  • Sealey MM20HV Digital Multimeter
  • Melato ea Teko (Bokhubelu le Botšo)
  • Thermocouple (Temperature Probe)
  • Bukana ea mosebelisi (tokomane ena)
Sealey MM20HV Digital Multimeter with test leads and thermocouple

Setšoantšo sa 1: Sealey MM20HV Digital Multimeter shown with included test leads and thermocouple.

4. Seta

4.1. Ho kenya Battery

The Sealey MM20HV requires two AAA batteries for operation.

  1. Fumana sekoahelo sa karolo ea betri ka morao ho multimeter.
  2. Sebelisa screwdriver ho tlosa screw e tiisang sekoahelo.
  3. Kenya libeteri tse peli tsa AAA, u shebe polarity e nepahetseng (+ le -) joalo ka ha ho bontšitsoe ka har'a karoloana.
  4. Tlosa sekoaelo sa karolo ea betri 'me u se sireletse ka screw.

4.2. Baetapele ba Liteko ba Hokelang

Proper connection of test leads is essential for accurate and safe measurements.

  • Insert the black test lead into the "COM" (Common) jack.
  • Bakeng sa boholo ba voltage, resistance, and continuity measurements, insert the red test lead into the "VΩmA" jack.
  • For high current (up to 10A DC) measurements, insert the red test lead into the "10A DC" jack. Ensure the function dial is set to the appropriate current range.
Sealey MM20HV Digital Multimeter with test leads connected

Setšoantšo sa 2: Multimeter with black lead in COM and red lead in VΩmA jack.

5. Litaelo tsa Ts'ebetso

The Sealey MM20HV offers 8 functions for various electrical measurements.

5.1. Matla On/O tima

Rotate the central function dial from the "OFF" position to any desired measurement function to turn the multimeter on. To turn off, rotate the dial back to "OFF".

5.2. Measuring DC Voltage (V=)

  1. Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
  2. Set the function dial to the desired DC Voltage range (e.g., 200mV, 2V, 20V, 200V, 600V). If the voltage is unknown, start with the highest range and decrease as necessary.
  3. Connect the test probes across the component or circuit to be measured.
  4. Bala voltage bohlokoa ponts'ong ea LCD.

5.3. Ho lekanya AC Moqtage (V~)

  1. Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
  2. Set the function dial to the desired AC Voltagmefuta e fapaneng (mohlala, 200V, 600V).
  3. Connect the test probes across the AC voltage mohloli.
  4. Bala voltage bohlokoa ponts'ong ea LCD.

5.4. Measuring DC Current (A=)

Tlhokomeliso: Never connect the multimeter in parallel with a voltage source when measuring current. Always connect in series with the load.

  1. Insert the black lead into the "COM" jack.
  2. For currents up to 200mA, insert the red lead into the "VΩmA" jack. For currents up to 10A, insert the red lead into the "10A DC" jack.
  3. Set the function dial to the appropriate DC Current range (e.g., 2mA, 20mA, 200mA, 10A).
  4. Bula potoloho moo hona joale ho lokelang ho lekanngoa teng 'me u hokahanye multimeter ka tatellano.
  5. Bala boleng ba hajoale ponts'ong ea LCD.

5.5. Measuring Resistance (Ω)

Tlhokomeliso: Netefatsa hore potoloho e felisitsoe matla 'me li-capacitor tsohle lia ntšoa pele ho lekanyetsoa khanyetso.

  1. Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
  2. Set the function dial to the desired Resistance range (e.g., 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ).
  3. Connect the test probes across the component whose resistance is to be measured.
  4. Bala boleng ba khanyetso ponts'ong ea LCD.

5.6. Teko ea Tsoelo-pele e Utloahalang

This function allows for quick checks of circuit continuity with an audible tone.

  1. Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
  2. Set the function dial to the continuity symbol (often shared with diode test).
  3. Connect the test probes across the circuit or component.
  4. An audible tone indicates continuity (low resistance). The display will show the resistance value.

5.7. Diode/Transistor Verification

This function allows for testing diodes and transistors.

  1. Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
  2. Set the function dial to the diode symbol.
  3. For diode testing, connect the red probe to the anode and the black probe to the cathode. The display will show the forward voltage drop. Reverse the probes; the display should show "OL" (Open Loop) for a good diode.
  4. For transistor (hFE) testing, insert the transistor leads into the appropriate NPN or PNP sockets on the multimeter. The display will show the hFE value.

5.8. Measuring Temperature (°C)

The multimeter includes a thermocouple for temperature measurements.

  1. Remove the test leads from the input jacks.
  2. Insert the thermocouple plug into the "VΩmA" and "COM" jacks, observing polarity if indicated.
  3. Set the function dial to the "°C" range.
  4. Place the tip of the thermocouple on or near the object whose temperature is to be measured.
  5. Read the temperature value in Celsius on the LCD display.

5.9. Mosebetsi oa ho Tšoara Lintlha

Press the "HOLD" button (typically a green button on the front panel) to freeze the current reading on the display. Press it again to release the hold and resume live readings.

6. Tlhokomelo

6.1. Ho hloekisa

Hlakola nyeoe ka papatsoamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is off and disconnected from any circuits before cleaning.

6.2. Phetoho ea Battery

When the battery indicator appears on the display, replace the batteries as described in Section 4.1. Always use fresh AAA batteries.

6.3. Fuse Replacement

If the current measurement function stops working, the fuse may need replacement.

  1. Ensure the multimeter is turned off and all test leads are disconnected.
  2. Remove the battery compartment cover and batteries.
  3. Locate the fuse(s) inside the compartment. The MM20HV typically uses a 200mA/250V fast-blow fuse for the mA range and a 10A/250V fast-blow fuse for the 10A range.
  4. Carefully remove the old fuse and replace it with a new fuse of the exact same type and rating.
  5. Replace the batteries and battery compartment cover.

Bohlokoa: Never use a fuse with a different rating or bypass a fuse. This can damage the multimeter and pose a serious safety hazard.

7. Ho rarolla mathata

BothataLebaka le ka khonehangTharollo
Ha ho pontsho kapa pontsho e lefifiLibetri tse shoeleng kapa tse tlaseReplace batteries (Section 4.1)
Litemana tse fosahetsengIncorrect range selected, poor lead connection, damaged leadsSelect appropriate range, ensure leads are fully inserted, inspect leads for damage and replace if necessary
Tekanyo ea hajoale ha e sebetseFuse e phatlohilengReplace fuse (Section 6.3)
"OL" (Ho jara ho feta tekano) ho bontshitsweMeasurement exceeds selected range, open circuit (for resistance/continuity)Select a higher range, check circuit for breaks

8. Litlhaloso

The following table outlines the technical specifications for the Sealey MM20HV Digital Multimeter.

TlhalosoBoleng
Mohlala No.MM20HV
BrandSealey
Mesebetsi8 (AC/DC Voltage, DC Current, Resistance, Temperature, Audible Continuity, Diode/Transistor Verification)
Mofuta oa AC Voltage (Accuracy)200V, 600V (±2%)
DC Moqtage (Accuracy)200mV, 2V, 20V, 200V, 600V (±0.5% to ±0.8%)
DC Current (Accuracy)2mA, 20mA, 200mA, 10A (±1% to ±2%)
Resistance (Accuracy)200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ (±0.8% to ±1%)
Mocheso RangeUp to 1000°C (with thermocouple)
Mohloli oa Matla2 x AAA Batteries
Boima ba Ntho0.29 Lik'hilograma (hoo e ka bang li-ounces tse 10.2)
Litekanyo (L x W x H)1.97 x 4.33 x 6.18 lisenthimithara
Maemo a TšireletsehoIEC 1010

Tlhokomeliso: Litlhaloso li ka fetoha ntle le tsebiso.

9. Tiisetso le Tšehetso

For information regarding warranty coverage, technical support, or service, please refer to the warranty card included with your product or contact Sealey customer service directly. Contact details are typically available on the manufacturer's official websebaka.

Litokomane tse Amanang - MM20HV

Peleview Sealey TA101 12 Function Digital Automotive Analyser User Manual
Comprehensive user manual for the Sealey TA101 12 Function Digital Automotive Analyser. Details safety precautions, technical specifications, operating procedures for various measurements, maintenance, and troubleshooting.
Peleview Sealey TM102 8-Function Professional Auto-Ranging Digital Multimeter - Buka ea Mosebelisi
Bukana e felletseng ea mosebelisi bakeng sa Sealey TM102 8-Function Professional Auto-Ranging Digital Multimeter. E kenyelletsa litaelo tsa polokeho, litlhaloso, tataiso ea ts'ebetso le mekhoa ea tlhokomelo.
Peleview Sealey MM19.V3 7-Function Digital Multimeter User Manual
Comprehensive user manual for the Sealey MM19.V3 7-Function Digital Multimeter, detailing safety instructions, specifications, features, and operation for AC/DC voltage, DC current, resistance, continuity, and transistor measurements.
Peleview Sesebediswa se Boima sa Mehala le Trolley ya Dikarolo e nang le Didrawer tse 5 le Top e Locklehang - Sealey AP890MHV
Litaelo le litlhaloso bakeng sa sesebelisoa sa mohala sa Sealey AP890MHV se boima bo boima le likarolo tsa trolley. Likarolo li kenyelletsa lithapo tse 5 tse nang le li-slide tse nang le libolo, sekoaelo se ka holimo se notlehang, le moralo o bonahalang haholo.
Peleview Sealey RS1312HV 900A 12V RoadStart Emergency Jump Starter - Buka ea Mosebelisi ea Hi-Vis Green
Bukana e felletseng ea mosebelisi bakeng sa Sealey RS1312HV 900A 12V RoadStart Emergency Jump Starter. E kenyelletsa litaelo tsa polokeho, litlhaloso, likarolo, tataiso ea ts'ebetso, mekhoa ea ho tjhaja, ho rarolla mathata le tlhahisoleseling ea ho sebelisa hape libeteri.
Peleview Sealey 1050CXLE v3 Trolley Jack Hydraulic Oil Safety Data Sheet
Leqephe la Boitsebiso ba Tšireletso bakeng sa Sealey 1050CXLE v3 Trolley Jack 2 Tonne Low Profile Oli e khutšoanyane ea Chassis Hydraulic, e hlalosang boitsebiso ba sehlahisoa, likotsi, thuso ea pele, ho tima mollo, ho tšoara, ho boloka, thepa ea 'mele le ho lahla.