Selelekela
This manual provides essential instructions for the safe and effective installation, operation, and maintenance of the Carrier HK61EA005 OEM Replacement Furnace Control Board. Please read this manual thoroughly before proceeding with any installation or service procedures. Retain this manual for future reference.
Boitsebiso ba Tšireletseho
TLHOKOMELISO: Installation and servicing of heating, ventilation, and air conditioning (HVAC) equipment can be hazardous due to system pressure, electrical components, and equipment location. Only trained and qualified service personnel should install, repair, or service HVAC equipment. Failure to follow these instructions could result in property damage, personal injury, or death.
- Always disconnect power to the furnace before installing or servicing the control board.
- Verify all wiring connections are secure and correct according to the furnace manufacturer's specifications.
- Apara lisebelisoa tse loketseng tsa ho itšireletsa (PPE), ho kenyeletsoa likhalase tsa tšireletso le liatlana.
- Ensure proper grounding of the furnace system.
Sehlahisoa se Felletseview
The Carrier HK61EA005 is an OEM replacement furnace control board designed to manage the operational sequences of a furnace, including ignition, fan control, and safety monitoring. This board is compatible with various Carrier furnace models.

Setšoantšo sa 1: Carrier HK61EA005 Furnace Control Board. This image displays the circuit board with various terminals, jumpers, and components. Key features include the "EASY SELECT" jumper settings for system type, ON/OFF DELAY settings, and terminal blocks for wiring connections such as D, R, W, W2, Y, Y2, G, O, and C. A yellow jumper wire is visible connecting two pins on the board.
Ho seta le ho Kenya
- Ho Khaoha ha Motlakase: Tima motlakase oohle o kenang ka ontong e ka sehloohong phanele ea tšebeletso. Netefatsa hore motlakase o timme u sebelisa voltage mitha.
- Phihlello ea Boto ea Khale: Bula phanele ea phihlello ea sebōpi ho fumana boto ea taolo e teng.
- Wiring ea litokomane: Before disconnecting any wires, take clear photographs or make a detailed diagram of all wiring connections to the old control board. Note the position and color of each wire.
- Hakolla Lithapo: Carefully disconnect all wires and connectors from the old control board.
- Tlosa Boto ea Khale: Unmount the old control board from the furnace chassis. Note how it was secured (screws, clips, etc.).
- Kenya Boto e Ncha: Mount the new HK61EA005 control board in the same location and orientation as the old board. Ensure it is securely fastened.
- Hokela Wiring: Refer to your photographs or diagram and carefully reconnect all wires and connectors to the corresponding terminals on the new control board. Double-check each connection for accuracy and tightness.
- Litlhophiso tsa Jumper: Configure the "EASY SELECT" jumpers and ON/OFF DELAY jumpers on the new board to match the settings of the original board or the furnace manufacturer's specifications. These settings typically determine the system type (e.g., AC, HP) and fan delay times. Refer to the furnace wiring diagram for specific requirements.
- Koala Phanele ea ho Kena: Once all connections are verified, close and secure the furnace access panel.
- Khutlisa Matla: Khutlisa motlakase ka setofong se phanele e kgolo ya tshebeletso.
Litaelo tsa Ts'ebetso
After successful installation and power restoration, the furnace control board will initiate its normal operating sequence. The board manages the following functions:
- Tatelano ea ho Ignition: Controls the gas valve and igniter for safe furnace startup.
- Taolo ea Balateli: Manages the indoor blower motor operation based on heating or cooling demands and delay settings.
- Tlhokomelo ea Tšireletseho: Continuously monitors various safety sensors (e.g., flame sensor, limit switches) and will shut down the furnace if a fault is detected.
- Thermostat Interface: Communicates with the thermostat to receive heating and cooling calls.
For specific operational details, refer to your furnace's primary instruction manual.
Tlhokomelo
The HK61EA005 control board itself requires no routine maintenance. However, regular maintenance of the overall furnace system is crucial for its longevity and proper function. This includes:
- Phetisetso ea Sesefe sa Moea: Replace or clean the furnace air filter regularly (typically every 1-3 months) to ensure proper airflow.
- Annual Professional Inspection: Have a qualified HVAC technician inspect and service your furnace annually.
- Clean Flame Sensor: A dirty flame sensor can cause intermittent furnace operation. This should be cleaned by a qualified technician.
Always disconnect power to the furnace before performing any maintenance.
Ho batle phoso
If the furnace is not operating correctly after installing the new control board, consider the following troubleshooting steps:
- Ha ho Matla:
- Check the circuit breaker for the furnace.
- Ensure the furnace disconnect switch is in the "ON" position.
- Netefatsa tsohle ka molumo o tlasetage le phahameng-voltage connections to the control board are secure.
- Furnace Not Igniting:
- Confirm the thermostat is set to "HEAT" and the temperature is above the ambient room temperature.
- Check for error codes on the control board (if applicable, refer to your furnace manual for code interpretations).
- Netefatsa hore phepelo ea peterole e bulehile.
- Verify the flame sensor is clean and properly positioned.
- Fan Not Operating Correctly:
- Check the "ON/OFF DELAY" jumper settings on the control board.
- Ensure the thermostat fan setting is correct (AUTO/ON).
- Verify the fan motor connections to the control board.
- Likhoutu tsa Phoso: Many control boards have diagnostic LEDs that flash codes to indicate specific faults. Consult your furnace's original manual for a list of error codes and their meanings.
If troubleshooting steps do not resolve the issue, contact a qualified HVAC technician for assistance.
Litlhaloso
| Nomoro ea Mohlala | HK61EA005 |
| Alternate Model Number | CECOMINOD058414 |
| Brand | Carrier (OEM Replacement) |
| Litekanyo tsa Sehlahisoa | 6 x 6 x 6 lisenthimithara |
| Boima ba 'mele | 0.01 lik'hilograma |
| Letsatsi le Fumanang Pele | La 8 Mphalane, 2013 |
Warranty le Tšehetso
For warranty information regarding this OEM replacement part, please refer to the terms provided by your original point of purchase or the specific warranty documentation included with the product. For technical support, it is recommended to consult a qualified HVAC technician or the original furnace manufacturer's support resources.