1. Selelekela
This manual provides comprehensive instructions for the safe and effective use of the PeakTech True RMS P 3131 Clamp Meter with Multimeter. This device is designed for measuring AC/DC currents without circuit interruption, as well as AC/DC voltage and resistance, with continuity testing capabilities. It features a 3 3/4 digit LCD display with True RMS measurement for accurate readings.
Ka kopo bala bukana ena ka botlalo pele o sebedisa sesebediswa mme o se boloke bakeng sa tshebediso ya sona nakong e tlang.
2. Boitsebiso ba Tšireletseho
WARNING: Improper use of this meter can cause damage, shock, injury, or death. Always follow all safety precautions.
- Kamehla khomarela mekhoa ea tšireletso ea lehae le ea naha.
- Do not use the meter if it appears damaged or if the insulation on test leads is compromised.
- Ensure the meter is set to the correct function and range before making measurements.
- Avoid contact with live circuits. Use appropriate personal protective equipment (PPE).
- The device is rated for CAT II 600V. Do not exceed these limits.
- Replace batteries promptly when the low battery indicator appears.
- Do not operate the meter in explosive atmospheres.
3. Sehlahisoa Overview le Likaroloana
The PeakTech P 3131 is a robust and reliable clamp meter. Familiarize yourself with its main components:

Setšoantšo sa 1: Pele view of the PeakTech P 3131 Clamp Meter, e bonts'a clamp jaw, function selector, LCD display, and input terminals.
- Clamp Mohlahare: For non-contact AC/DC current measurement.
- Function Selector Dial: To select measurement modes (A~, A=, V~, V=, Ω/Continuity, OFF).
- Pontšo ea LCD: E bonts'a lipalo tsa litekanyo, li-unit, le li-index.
- Likonopo: AC/DC, ZERO, H/MAX (Data Hold/Max Hold).
- Lits'ebetso tsa ho kenya: COM (common) and VΩ (voltage/resistance) for test leads.
- Hand Guard: Provides protection against accidental contact.
4. Seta
4.1 Ho kenya Betri
The PeakTech P 3131 requires two 1.5V AAA batteries (included). To install or replace batteries:
- Netefatsa hore sesebelisoa se koetsoe.
- Locate the battery compartment cover on the rear of the meter.
- Sebelisa screwdriver ho bula phaposi.
- Insert the two AAA batteries, observing correct polarity (+ and -).
- Tlosa sekoaelo sa karolo ea betri 'me u se sireletse ka screw.
When the low battery indicator appears on the display, replace the batteries immediately to ensure accurate measurements.
4.2 Ho kopanya Lieta tsa Tlhahlobo
Bakeng sa voltage, resistance, and continuity measurements, connect the supplied test leads:
- Kenya black test lead in the COM (common) input terminal.
- Kenya tlhahlobo e khubelu ea teko ho VΩ terminal ea ho kenya.

Figure 2: PeakTech P 3131 Clamp Meter shown with its carrying case, test leads, batteries, and user manual.
5. Litaelo tsa Ts'ebetso
5.1 Ho Bulela/Ho tima
Rotate the function selector dial from the "OFF" position to any desired measurement function to power on the meter. To power off, rotate the dial back to "OFF". The meter features an automatic power-off function (can be deactivated) to conserve battery life.
5.2 Tekanyo ea Hona Joale ea AC/DC (Clamp)
To measure current without breaking the circuit:
- Fetolela sekhetho sa tšebetso ho daela ho A~ (Motlakase oa AC) kapa A= (DC Current) position.
- Tobetsa ea AC/DC button if you need to switch between AC and DC current modes (if the dial position combines them).
- Tobetsa ea ZERO button to zero the display before measuring DC current, especially for small currents, to compensate for residual magnetism.
- Bula clamp mohlahare ka ho toboketsa setlokotsebe.
- Enclose only ngoe conductor with the clamp mohlahare. Netefatsa hore mohlahare o koetsoe ka botlalo.
- Bala boleng ba hajoale ponts'ong ea LCD.

Figure 3: The PeakTech P 3131 Clamp Meter in use, measuring current on a single conductor within an electrical panel.
5.3 AC/DC Moqtage Tekanyo
Ho lekanya voltage:
- Hokela lintlha tsa tlhahlobo joalo ka ha ho hlalositsoe Karolong ea 4.2.
- Fetolela sekhetho sa tšebetso ho daela ho V~ (Moqolo oa ACtage) kapa V= (DC Moqtage) boemo.
- Connect the test probes in parallel to the circuit or component you wish to measure.
- Bala voltage bohlokoa ponts'ong ea LCD.
5.4 Resistance and Continuity Measurement
To measure resistance or check for continuity:
- Hokela lintlha tsa tlhahlobo joalo ka ha ho hlalositsoe Karolong ea 4.2.
- Fetolela sekhetho sa tšebetso ho daela ho Ω/))) (Resistance/Continuity) position.
- For resistance: Connect the test probes across the component. Ensure the circuit is de-energized.
- For continuity: Touch the test probes to the two points you want to check. A continuous beep indicates a low-resistance path (continuity).
- Bala boleng ba khanyetso ponts'ong ea LCD.
5.5 Mesebetsi e Ikgethileng
- RMS ea 'nete: The meter measures True Root Mean Square values for AC voltage and current, providing accurate readings for non-sinusoidal waveforms.
- Data Hold (H): Tobetsa ea H/MAX konopo ka bokgutshwane ho hoamisa palo ya hajwale pontshong. Tobetsa hape ho lokolla.
- Maximum Value Hold (MAX): Tobetsa o hatelle H/MAX button to capture and display the maximum measured value. Press again to exit.
- ZERO Function: Used to zero the display for DC current measurements to eliminate offset errors.
- Tekanyo ea Othomathiki: The meter automatically selects the appropriate measurement range.
- Motlakase oa Motlakase: The meter automatically turns off after a period of inactivity to save battery. This feature can typically be disabled by holding a specific button during power-on (refer to the device's on-screen indicators or a more detailed manual if available).
6. Tlhokomelo
6.1 Ho hloekisa
Hlakola lebokose la mithara ka papatsoamp lesela le sesepa se bonolo. U se ke ua sebelisa li-abrasives kapa solvents. Netefatsa hore mitha e omme ka botlalo pele o sebelisoa.
6.2 Phetoho ea Betri
Refer to Section 4.1 for instructions on battery replacement. Always use two fresh 1.5V AAA batteries. Remove batteries if the meter is not used for an extended period to prevent leakage.
6.3 Polokelo
Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided carrying case for protection.
7. Ho rarolla mathata
| Bothata | Lebaka le ka khonehang | Tharollo |
|---|---|---|
| Metara ha e sebetse. | Libetri tse shoeleng kapa tse kentsoeng ka phoso. | Sheba polarity ea betri; fetola libeteri. |
| "OL" or "OVER" displayed. | Measurement exceeds selected range or meter's maximum capacity. | Select a higher range (if manual ranging) or ensure measurement is within meter's limits. |
| Inaccurate DC current reading. | Residual magnetism in clamp mohlahare. | Tobetsa ea ZERO button before measurement. |
| Ha ho bipi e tsoelang pele. | Open circuit or high resistance. | Check connections; ensure circuit is complete. |
If problems persist, contact PeakTech customer support or a qualified service technician.
8. Lintlha tsa Setegeniki
| Paramethara | Tlhaloso |
|---|---|
| Pontšo | 3 3/4 digit LCD, max. 3999 counts |
| DC Moqtage (DCV) | 0.1 mV to 600 V (Accuracy: 0.5% + 2 digits) |
| Mofuta oa AC Voltage (ACV) | 1 mV to 600 V (Accuracy: 1.5% + 5 digits) |
| DC Hajoale (DCA) | 10 mA to 300 A (Accuracy: 1% + 2 digits) |
| AC Hajoale (ACA) | 10 mA to 300 A (Accuracy: 1% + 3 digits) |
| Khanyetso (Ω) | 0.1 Ω to 40 MΩ (Accuracy: 0.9% + 2 digits) |
| Tsoelo-pele Test | Mosebetsi oa buzzer |
| RMS ea 'nete | Yes, for AC measurements |
| Ho Bula Mohlahare | 22 mm max. conductor diameter |
| Lintlha tsa polokeho | EN 61010-1, CAT II 600 V |
| Phepelo ea motlakase | 2 x 1.5V libeteri tsa AAA |
| Litekanyo (L x W x H) | 192 x 66 x 27 mm (hoo e ka bang 7.56 x 2.6 x 1.06 inches) |
| Boima ba 'mele | 205 g (hoo e ka bang 0.45 lbs) |
9. Tiisetso le Tšehetso
PeakTech products are manufactured under strict quality control. This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product or visit the official PeakTech websebaka bakeng sa lintlha le lipehelo tse qaqileng tsa tiisetso.
For technical support, service, or calibration inquiries, please contact your local PeakTech distributor or the PeakTech customer service department. Contact information can typically be found on the PeakTech websetsheng kapa sephuthelong sa sehlahiswa.