1. Sehlahisoa Overview
The KING LPWV2715-CT24 is a robust, vandal-resistant electric heater designed for high-traffic and public areas such as detention facilities, public restrooms, and rest areas. Its heavy-duty construction, including a 3/16-inch solid steel frame and grill, provides exceptional durability against impact and abuse. Tamper-resistant screws secure the grill, and controls are recessed to prevent unauthorized access. This unit offers moderate wattage and high airflow to effectively heat entryways and hallways, preventing drafts from affecting the building's core temperature.

Setšoantšo sa 1: Pele view of the KING LPWV2715-CT24 Vandal Resistant Heater, showcasing its robust metal casing and grill.
Likarolo tsa Bohlokoa:
- Impact/Vandal Resistant: Constructed with a heavy grill and 3/16-inch solid steel frame.
- Pic-A-Watt Elements: Allows for multiple wattage options to suit specific heating requirements.
- Tamper Resistant 3 Position Switch: Offers Fan, Heat, and Off settings, designed to prevent unauthorized adjustments.
- Tšireletso ea mocheso o feteletseng: Integrated safety feature to prevent overheating.
2. Boitsebiso ba Tšireletseho
Read all instructions carefully before installing or using this heater. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.
- Kemiso ea Motlakase: This heater operates on 277 Volts and requires hardwiring. Installation must be performed by a qualified electrician in accordance with all national and local electrical codes.
- Ho beha fatše: This heater must be properly grounded to reduce the risk of electric shock.
- Sebaka: Do not install the heater in areas where gasoline, paint, or other flammable liquids are stored or used. Maintain proper clearances from combustible materials as specified in the installation section.
- Tšireletso ea mocheso o feteletseng: The heater is equipped with a thermal cut-out to prevent overheating. If the heater shuts off due to overheating, allow it to cool down before attempting to restart. Investigate and correct the cause of overheating.
- Se Koahele: Never cover the heater or block its air inlets/outlets. This can cause overheating and fire.
- Tlhokomelo: Tlosa motlakase pele o lokisa kapa ho hloekisa.
3. Likahare tsa Sephutheloana
Netefatsa hore likarolo tsohle li teng ebile ha lia senyeha ha u bula sephutheloana:
- KING LPWV2715-CT24 Vandal Resistant Heater Unit
- Mounting Hardware (typically included)
- Buka ea litaelo (tokomane ena)
Haeba lintho life kapa life li le sieo kapa li senyehile, ikopanye le mofani oa thepa ea hau hang-hang.
4. Ho kenya
TLHOKOMELISO: Installation must be performed by a qualified electrician. Disconnect all power to the circuit at the main service panel before attempting any wiring.
Sebaka sa Mounting
- This heater is designed for indoor, wall-mount installation.
- Choose a location that allows for proper air circulation and maintains required clearances from walls, ceilings, and floors. Refer to local codes for specific clearance requirements.
- Ensure the mounting surface is structurally sound to support the heater's weight (approximately 36 pounds).
4.2 Khokelo ea Motlakase
- The LPWV2715-CT24 heater requires a dedicated 277 Volt, 60 Hz, single-phase circuit.
- Heatha e hula 5.4 Amps at 277V, providing 1500 Watts of heat. Ensure the circuit breaker and wiring are appropriately sized for this load.
- Connect the heater directly to the electrical supply using appropriate hardwiring methods and connectors, following the wiring diagram provided inside the heater's access panel.
- Netefatsa hore likhokahano tsohle li tiile ebile li bolokehile.
5. Ts'ebetso
Once properly installed and powered, the heater can be operated using its tamper-resistant 3-position switch.
5.1 Li-setting tsa Power Switch
- TIMA: The heater is completely off, and no heat or fan operation will occur.
- FANANE: The fan operates continuously without engaging the heating elements. This can be used for air circulation.
- MOCHESO: The heating elements and fan operate to provide warmth. The heater will cycle on and off to maintain the desired temperature if connected to an external thermostat (not included).
5.2 Wattage Selection (Pic-A-Watt)
The LPWV series heaters feature Pic-A-Watt elements, allowing for field-adjustable wattage settings. Refer to the wiring diagram inside the heater for instructions on how to adjust the wattage to suit specific room requirements. This adjustment should only be performed by a qualified technician with power disconnected.
6. Tlhokomelo
Tlhokomelo e tloaelehileng e netefatsa ts'ebetso e ntle le nako e telele ea heater ea hau. Kamehla tima motlakase ho circuit breaker pele o etsa tlhokomelo efe kapa efe.
- Ho hloekisa: Nako le nako hloekisa bokantle ba hitara ka damp lesela. Se ke oa sebelisa li-abrasive cleaners kapa solvents.
- Libaka / Lits'oants'o tsa Moea: Ensure that the air inlets and outlets are free from dust, lint, and other obstructions. Use a vacuum cleaner with a brush attachment to gently clean the grill and internal components if accessible.
- Tlhahlobo: Annually inspect the heater for any signs of damage, loose wiring, or unusual wear. If any issues are found, contact a qualified electrician for repair.
7. Ho rarolla mathata
Pele o ikopanya le tšehetso ea bareki, review lintlha tse latelang tse tloaelehileng le tharollo:
| Bothata | Lebaka le ka khonehang | Tharollo |
|---|---|---|
| Heatara ha e bulele. | No power supply; Circuit breaker tripped; Loose wiring. | Check circuit breaker; Ensure power switch is in 'HEAT' or 'FAN' position; Consult a qualified electrician to check wiring. |
| Heater produces no heat, but fan runs. | Switch in 'FAN' position; Heating elements failed; Overheat protection activated. | Set switch to 'HEAT'; Allow heater to cool if overheat protection tripped; Contact a qualified electrician for element inspection. |
| Heatara e bulela le ho tima khafetsa. | Improper thermostat setting (if applicable); Restricted airflow; Overheat protection cycling. | Adjust thermostat setting; Clear any obstructions from air inlets/outlets; Ensure proper clearances. |
| Unusual noises or odors. | Loose components; Dust accumulation on elements; Motor issue. | Disconnect power immediately; Inspect for loose parts; Clean heater; Contact a qualified electrician for inspection. |
Haeba bothata bo ntse bo tsoela pele ka mor'a ho leka litharollo tsena, ikopanye le tšehetso ea bareki kapa setsebi sa motlakase se tšoanelehang.
8. Litlhaloso
| Tlhaloso | Lintlha |
|---|---|
| Brand | MORENA |
| Nomoro ea Mohlala | LPWV2715-CT24 |
| Moqtage | Li-volts tse 277 |
| Ampkhalefo | 5.4 Amps |
| Wattage | 1500 Watts |
| Litekanyo tsa Sehlahisoa (D x W x H) | 4"D x 13.75"W x 22.75"H |
| Boima ba Ntho | 36 liponto |
| Mofuta oa ho Beha | Thaba ea Lerako |
| Mofuta oa Mafura | Motlakase |
| Tšebeliso ea Ka hare/Kantle | Ka hare |
| Tšobotsi e Khethehileng | Tšireletso ea mocheso o feteletseng |
| UPC | 093319183731 |
| ASIN | B0G3SWW2XK |
9. Tiisetso le Tšehetso
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official KING websebaka. Boloka rasiti ea hau ea theko e le bopaki ba hore u rekile litseko tsa waranti.
Moetsi: KING Electrical Manufacturing
Websebaka: www.king-electric.com (Exampsehokelo, ka kopo netefatsa semmuso websaete)