AKO D-14323

AKO D-14323 230V Universal Digital Temperature Controller User Manual

1. Selelekela

This manual provides essential information for the proper installation, operation, and maintenance of the AKO D-14323 230V Universal Digital Temperature Controller. Designed for industrial and commercial refrigeration applications, this controller offers precise temperature management and adjustable defrost cycles. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

2. Boitsebiso ba Tšireletseho

Kamehla ela hloko mehato e latelang ea tšireletso ho thibela kotsi ea motho kapa tšenyo ea sesebelisoa:

  • Ho kenya le ho lokisa ho lokela ho etsoa feela ke basebetsi ba tšoanelehang.
  • Disconnect power to the unit before performing any wiring or maintenance.
  • Etsa bonnete ba hore motlakase o na le voltage matches the controller's specifications (230V).
  • Protect the device from water, moisture, and extreme temperatures.
  • Do not open the controller housing unless specifically instructed.

3. Sehlahisoa Overview

The AKO D-14323 is a versatile digital temperature controller equipped with a clear digital display and intuitive controls. It is suitable for a wide range of refrigeration and freezer units.

Likarolo tsa Bohlokoa:

  • Digital thermostat for industrial and commercial freezers.
  • Temperature range from -50.0 °C to +99.9 °C (-58°F to +210.2°F).
  • Three relays for compressor, fan, and auxiliary functions.
  • Two temperature sensors included.
  • Panel mounting design.
  • Programmable defrost cycles.
  • Fahrenheit and Celsius readings.
  • Programmable digital inputs for door switch, alarm, remote defrost, energy saving, or continuous cycle.

Controller Front Panel:

Pele view of AKO D-14323 Temperature Controller

Setšoantšo sa 3.1: Pele view of the AKO D-14323 controller, showing the digital display and control buttons. The display shows temperature readings, and buttons include ESC, SET, Power, and up/down arrows (often used for defrost and parameter adjustment).

The front panel features a digital display for temperature readings and status indicators. Control buttons allow for setting parameters, initiating defrost cycles, and navigating menus.

4. Ho kenya le ho seta

Proper installation is crucial for the controller's performance and longevity.

4.1 Ho Beha Phanele

The AKO D-14323 is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals.

4.2 Likhokelo tsa Motlakase

Refer to the wiring diagram on the back of the unit for correct electrical connections. All wiring must comply with local electrical codes.

Morao view of AKO D-14323 Temperature Controller with wiring diagram

Setšoantšo sa 4.1: Morao view of the AKO D-14323 controller, displaying the wiring diagram and product specifications. This diagram illustrates connections for power (230V), sensors (S1, S2), compressor (COOL), fan, and auxiliary outputs, along with digital inputs (D1, D2).

Wiring Key Points:

  • Phepelo ea motlakase: Connect 230V AC to the designated terminals.
  • Sensora: Connect the two temperature sensors (S1, S2) to their respective terminals.
  • Relay Outputs: Connect the compressor, fan, and auxiliary loads to their corresponding relay terminals. The diagram specifies maximum current ratings for each output (e.g., COOL: 12(9)A 250V~, FAN: 5(4)A 250V~, AUX: 8(4)A 250V~).
  • Litlhahiso tsa dijithale: Utilize terminals for programmable digital inputs such as door switches or external alarms.

4.3 Matlafatso ea Pele

After wiring, apply power to the controller. The display should illuminate, showing the current temperature or an initial setup prompt.

5. Litaelo tsa Ts'ebetso

The AKO D-14323 offers various programmable parameters to suit different refrigeration needs.

5.1 Ts'ebetso ea Motheo

  • Pontšo ea Mocheso: The main display shows the current temperature measured by the primary sensor.
  • SET Konope: Tobetsa ho view or modify the setpoint temperature. Hold to enter parameter programming mode.
  • Konopo ea ESC: Used to exit menus or cancel changes.
  • Metsu ea holimo/ea Tlase: Used to adjust values in programming mode or manually initiate defrost (if configured).
  • Konopo ea Matla: Turns the unit on/off or acts as a reset in some configurations.

5.2 Setting the Temperature Setpoint

  1. Tobetsa ea HLOKOMELA button briefly. The current setpoint will flash.
  2. Sebelisa le Up or Tlase arrow buttons to adjust the desired temperature.
  3. Tobetsa HLOKOMELA again to confirm and save the new setpoint, or ESC ho tsoa ntle le ho boloka.

5.3 Advanced Parameter Programming

To access advanced parameters (e.g., defrost cycles, differential, auxiliary relay functions), hold the HLOKOMELA button for several seconds until the first parameter code appears. Navigate using the arrow buttons and press HLOKOMELA to enter/confirm values. Refer to the detailed programming guide (usually provided separately or available from AKO) for a complete list of parameters and their functions.

5.4 Defrost Cycle Management

The controller supports various defrost methods, including controlling the compressor, resistance heaters, or fans. Defrost parameters can be adjusted to optimize performance based on the application. An optional probe allows defrosting by temperature.

6. Tlhokomelo

Regular maintenance ensures optimal performance and extends the lifespan of your temperature controller.

  • Ho hloekisa: Hloekisa phanele e ka pele nako le nako ka lebone le bonolo, damp lesela. Se ke oa sebelisa li-abrasive cleaners kapa solvents.
  • Litlhahlobo: Regularly check wiring connections for tightness and signs of wear or corrosion.
  • Tlhahlobo ea Sensor: Ensure temperature sensors are securely in place and free from damage.

For any internal maintenance or repairs, contact a qualified technician.

7. Ho rarolla mathata

If you encounter issues with your AKO D-14323 controller, refer to the following common problems and solutions:

BothataLebaka le ka khonehangTharollo
Pontšo ha e na lethoNo power supply; incorrect wiringCheck power connections and ensure 230V supply. Verify wiring according to the diagram.
Ho bala mocheso o fosahetsengFaulty sensor; sensor not properly connected or placedCheck sensor connections. Replace sensor if damaged. Ensure sensor is correctly positioned in the controlled environment.
Compressor/Fan not operatingSetpoint issue; relay fault; wiring error; parameter misconfigurationVerify setpoint and differential settings. Check wiring to the compressor/fan. Review advanced parameters for correct configuration.
Defrost not initiatingDefrost parameters incorrect; manual defrost not triggeredCheck defrost cycle settings (interval, duration, temperature). Attempt manual defrost if configured.

If the problem persists after attempting these solutions, contact AKO technical support or a qualified service technician.

8. Litlhaloso

Detailed technical specifications for the AKO D-14323 controller:

  • Mohlala: AKO D-14323
  • Moqtage: Li-volts tse 230
  • Boemo ba Mocheso: -50.0 °C to +99.9 °C (-58°F to +210.2°F)
  • Lisebelisoa: 3 (Compressor, Fan, Auxiliary)
  • Sensora: 2 temperature sensors included
  • Ho hlongoa: Ho kenya liphanele
  • Boitsebiso: Plastiki
  • Boima ba Ntho: 0.01 ounces (hoo e ka bang)
  • Setaele sa Pontšo: Dijithale
  • Likarolo tse Khethehileng: E ka reroang
  • Tšebeliso: Khoebo / Bolulo
  • Setifikeiti: ETL, CE, IP65, GAMA
  • Moetsi: AKOCONTROL

9. Tiisetso le Tšehetso

For warranty information and technical support, please contact AKO directly or refer to their official websebaka. Boloka rasiti ea hau ea theko bakeng sa likopo tsa tiisetso.

Moetsi: AKOCONTROL
Websebaka: www.ako.com

© 2023 AKO. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.