LogTag UTRIX-16

LogTag UTRIX-16 PDF Temperature Data Logger User Manual

Model: UTRIX-16

1. Selelekela

Lenaneo la LogTag UTRIX-16 is a high-performance, multi-use temperature data logger designed for reliable and accurate monitoring across a wide range of applications. This device records temperature data and generates comprehensive PDF reports without requiring special software or hardware. Its integrated USB connector allows for easy data transfer and configuration.

2. Boitsebiso ba Tšireletseho

  • Do not expose the device to extreme physical shock or vibration.
  • Avoid immersing the device in liquids.
  • Do not attempt to open or modify the device, as this will void the warranty and may cause damage.
  • Lahla libeteri ho latela melao ea lehae.
  • Ensure the USB connector is clean and dry before connecting to a computer.

3. Likahare tsa Sephutheloana

Netefatsa hore lintho tsohle li teng ka har'a sephutheloana:

  • LogTag UTRIX-16 PDF Temperature Data Logger
  • Bukana ea mosebelisi (tokomane ena)

4. Sesebelisoa Overview

The UTRIX-16 features a compact design with clear indicators and control buttons.

LogTag UTRIX-16 front view with indicators and buttons

Setšoantšo sa 1: Pele view of the LogTag UTRIX-16 PDF Temperature Data Logger. This image displays the device's front panel, showing the "ALERT" and "OK" indicator lights, and the "STOP" and "START/Mark" buttons. The LogTag brand and "USB PDF TEMPERATURE RECORDER" text are visible, along with a serial number barcode.

  • ALERT Indicator: Flashes when a pre-configured temperature alert threshold has been exceeded.
  • OK Indicator: Flashes to confirm normal operation and within-range temperature readings.
  • STEP Konopo: Press to stop the current logging session.
  • START/Mark Button: Press to start a new logging session or to insert a mark into the data stream during logging.
  • Integrated USB Connector: Located at the bottom, used for connecting to a computer for configuration and data download.
LogTag UTRIX-16 with USB connector extended

Setšoantšo sa 2: Lenaneo la LogTag UTRIX-16 with its integrated USB connector extended. This view highlights the USB-A plug, ready for connection to a computer's USB port, facilitating direct data transfer and device configuration.

5. Seta

5.1 Tlhophiso ea Pele

The UTRIX-16 is typically pre-configured for immediate use. However, for custom settings (e.g., logging interval, alert thresholds, start delay), you will need to use the LogTag Analyzer software. This software is available for download from the official LogTag websebaka.

  1. Download and install the LogTag Analyzer software e tsoang ho LogTag Recorders Software.
  2. Connect the UTRIX-16 to a USB port on your computer.
  3. LogTag UTRIX-16 plugged into a computer USB port

    Setšoantšo sa 3: Lenaneo la LogTag UTRIX-16 data logger connected to a computer's USB port. This illustrates the direct connection method for data download and configuration, eliminating the need for a separate interface cradle.

  4. Lenaneo la LogTag Analyzer software should automatically detect the connected device.
  5. Follow the on-screen prompts within the software to configure logging parameters as needed.

5.2 Litaba tsa Battery

The UTRIX-16 uses a CR2 battery (included). The battery is designed for long life and is generally not user-replaceable without specialized tools. If battery replacement is required, it is recommended to contact LogTag support or an authorized service center.

6. Ts'ebetso

6.1 Starting a Logging Session

To start a new logging session:

  1. Ensure the device is not currently logging (check the OK/ALERT indicators).
  2. Tobetsa o hatelle QALA/Tšoaea button for approximately 5 seconds until the OK indicator flashes rapidly.
  3. Release the button. The OK indicator will flash at regular intervals, indicating that logging has started.

6.2 Ho Emisa Seboka sa ho Rema Lihlahla

To stop an active logging session:

  1. Tobetsa o hatelle EMA button for approximately 5 seconds until the ALERT indicator flashes rapidly.
  2. Release the button. The device will cease logging.

6.3 Marking Data

During an active logging session, you can insert a mark into the data stream:

  • Tobetsa konopo ea QALA/Tšoaea button (less than 2 seconds).
  • A mark will be recorded in the data, visible when the data is downloaded and analyzed.

7. Data Retrieval and Reporting

The UTRIX-16 generates a PDF report directly when connected to a computer.

  1. Connect the UTRIX-16 to a USB port on your computer.
  2. The device will appear as a removable drive.
  3. Locate and open the generated PDF report file. This report contains a summary of the logging session, temperature graphs, and statistical data.
  4. For advanced analysis and configuration, use the LogTag Software ea Analyzer.

8. Tlhokomelo

8.1 Ho hloekisa

Hlakola sesebelisoa ka mohala o bonolo, damp lesela. Se ke oa sebelisa li-abrasive cleaners kapa solvents.

8.2 Phetoho ea Betri

The battery in the UTRIX-16 is designed for extended use and is not intended for user replacement. If the battery life is depleted, contact LogTag support for service options.

9. Ho rarolla mathata

Bothata Lebaka le ka khonehang Tharollo
Device does not start logging. Incorrect button press duration; device already logging; battery depleted. Ensure the START/Mark button is held for approximately 5 seconds. Check if the device is already logging. Connect to LogTag Analyzer to check battery status.
Khomphutha ha e tsebe sesebediswa. Loose USB connection; faulty USB port; driver issue. Ensure the USB connector is fully inserted. Try a different USB port. Reinstall LogTag Software ea Analyzer.
Ha ho tlaleho ea PDF e hlahisitsoeng. Logging session not completed; device not recognized as a drive. Ensure the logging session has been stopped. Verify the device appears as a removable drive.
ALERT indicator flashing. Temperature exceeded pre-set limits. This indicates an alert condition. Review the PDF report or LogTag Analyzer data to identify when and for how long the limits were exceeded.

10. Litlhaloso

Sebopeho Lintlha
Nomoro ea Mohlala UTRIX-16
Mocheso Range -25°C ho ea +70°C (-13°F ho ea +158°F)
Khokahano USB e kopantsoeng
Mohloli oa Matla 1 CR2 betri (e kenyelelitsoe)
Litekanyo tsa Sehlahisoa 3.66 x 2.15 x 0.34 lisenthimithara
Boima ba 'mele 1.27 lik'hilograma
Lintho tse bonahalang Plastiki
Tšobotsi e Khethehileng High Accuracy, PDF Reporting

11. Tiisetso le Tšehetso

LogTag products are manufactured to high standards. For warranty information and technical support, please refer to the official LogTag websaete kapa ikopanye le morekisi oa lehae oa hau. Boloka rasiti ea hau ea theko e le bopaki ba hore u rekile.

Official LogTag Websebaka: www.logtag-rekoto.com

© 2023 LogTag. Litokelo tsohle li sirelelitsoe.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.