DIGITUS DN-93903

DIGITUS DN-93903 Cat 6 LSA Connection Module User Manual

Model: DN-93903 | Brand: DIGITUS

1. Sehlahisoa Overview

The DIGITUS DN-93903 LSA connection module is designed for connecting or extending twisted pair cables. It provides excellent performance and connection quality for your network infrastructure.

This shielded Cat 6 LSA insulation displacement connector supports transmission characteristics up to 250 MHz and 1GBase-T applications. It is suitable for AWG 22 to AWG 26 solid and stranded conductors.

The module is versatile, suitable for installation in cable ducts, flush-mounted, and surface-mounted applications. It is ideal for extending existing cables or replacing defective cable sections in your network setup.

DIGITUS LSA connection module with color-coded wiring diagram

Image: The DIGITUS LSA connection module showing the internal LSA terminals with color-coded wiring for EIA/TIA 568 A & B standards. An Ethernet cable is connected to a wall outlet, illustrating a typical application.

2. Litaelo tsa ho seta

Follow these steps to properly install and connect the DIGITUS DN-93903 LSA connection module:

  1. Lokisa Lithapo: Strip approximately 2-3 cm of the outer jacket from the installation cables you intend to connect. Ensure the twisted pairs remain intact.
  2. Open Module: Carefully open the LSA connection module to access the LSA insulation displacement terminals.
  3. Thibelo ea Mehala: Refer to the color-coded wiring diagram on the LSA terminals (EIA/TIA 568 A or B standard). Untwist the wire pairs minimally and place each individual wire into the corresponding slot on the LSA terminal.
  4. Secure Wire: Use an LSA punch-down tool (not included) to press each wire firmly into its slot. The tool will simultaneously cut off any excess wire. Ensure a secure connection.
  5. Integrated Strain Relief: Utilize the integrated strain relief mechanism to secure the incoming cables, preventing accidental disconnections or damage.
  6. Close Module: Once all wires are correctly terminated and secured, carefully close the module housing.
  7. Ho hlongoa: Mount the module in your desired location (panel, flush-mounted box, or surface-mounted) using appropriate fasteners (not included).

3. Litaelo tsa Ts'ebetso

The DIGITUS DN-93903 LSA connection module is a passive component designed for permanent cable connections. Once installed, it operates without user intervention.

  • Mosebetsi: The module extends or connects two network installation cables, maintaining the Cat 6 performance standards.
  • Khokahano: Ensure that the connected cables are properly terminated and connected to active network equipment (e.g., switches, routers) for network functionality.
  • Tshebetso: When correctly installed, the module facilitates data transmission up to 1 Gigabit Ethernet (1GBase-T) with a bandwidth of 250 MHz.

4. Tlhokomelo

The DIGITUS DN-93903 LSA connection module requires minimal maintenance due to its robust design.

  • Ho hloekisa: Boloka mojule o se na lerōle le lithōle. Sebelisa lesela le bonolo, le omileng bakeng sa ho hloekisa. U se ke ua sebelisa li-cleaner tsa metsi kapa li-solvent.
  • Maemo a Tikoloho: Ensure the module is installed in a dry indoor environment, away from excessive moisture, heat, or direct sunlight.
  • Litlhahlobo: Periodically check the cable connections for any signs of wear, damage, or loose wires. Re-terminate if necessary.

5. Ho rarolla mathata

If you experience network connectivity issues after installing the LSA connection module, consider the following troubleshooting steps:

  • Ha ho Khokahano ea Marang-rang:
    • Verify that all wires are correctly terminated according to the EIA/TIA 568 A or B standard. Incorrect wiring is a common cause of connection failure.
    • Ensure that the LSA punch-down tool was used correctly, making firm contact and cutting excess wire.
    • Check the integrity of the connected network cables. Test them individually if possible.
    • Confirm that all active network equipment (router, switch, PC) is powered on and functioning correctly.
  • Lebelo le Butle la Netweke:
    • Ensure that all connections are secure and that no wires are loose or partially disconnected.
    • Verify that the cables used are Cat 6 compliant to match the module's performance.
    • Check for external interference if the module is installed near power cables or other sources of electromagnetic interference. The module is shielded, but proper installation practices are still important.
  • Khokahano ea nakoana:
    • Re-examine the LSA terminations for any wires that may have come loose or were not fully seated.
    • Ensure the module housing is securely closed and the strain relief is properly applied.

6. Litlhaloso

SebopehoTlhaloso
MohlalaEA-93903-DN
Litšobotsi tsa phetisoSehlopha sa 6
Libaka tsa KopoUp to 250 MHz, 1GBase-T
LitekanyetsoISO/IEC 11801 3rd Edition, EN 50173-1, EIA/TIA 568-C, ANSI, UL
Mofuta oa TlhophisoSuitable for duct, flush-mounted, and surface-mounted installation
Kemiso ea CableLSA-strips, color-coded according to EIA/TIA 568 A & B
Conductor AcceptanceAWG 22-26 solid and stranded conductors
Thepa ea MatloABS UL-94V-0
RJ45 Jack Contact MaterialNickel-plated phosphor bronze, 0.5 µ gold-plated contact
RJ-45 Shielding MaterialNickel-plated bronze
LSA Cutting Clamp Lintho tse bonahalangKrone LSA+, UL 94V-0, galvanized phosphor bronze
PCBFR4, UL 94V-0
Mocheso oa ho sebetsa-20°C ho ea ho +70°C
Khanyetso ea Insulation> 500 MOhm
Ikopanye le Resistance< 20 milliOhm
Matla a Dielectric1000 VDC (contact/contact), 1500 VDC (contact/ground)
Litekanyo tsa Sehlahisoa (D x W x H)15D x 9B x 3H disentimitara
DIGITUS LSA connection module with dimensions shown in inches and centimeters

Setšoantšo: Haufi view of the DIGITUS LSA connection module, illustrating its compact size with dimensions of 2.6 inches (6 cm) in length.

7. Tiisetso le Tšehetso

Boitsebiso ba Warranty

This DIGITUS DN-93903 LSA Connection Module comes with a 2-year legal warranty. Ka kopo, boloka bopaki ba theko bakeng sa likopo life kapa life tsa waranti.

Tšehetso ea tekheniki

For technical assistance, installation queries, or troubleshooting beyond the scope of this manual, please contact DIGITUS customer support. Refer to the official DIGITUS websaete kapa sephutheloana sa sehlahisoa sa hau bakeng sa tlhaiso-leseling ea morao-rao ea puisano.

When contacting support, please have your product model number (DN-93903) and a detailed description of your issue ready.

© 2023 DIGITUS. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.