This instruction manual provides essential information for the safe installation, operation, and maintenance of your Leviton 7591-PLG 15-Amp, 125-Volt Smart Lock GFCI Single Outlet with LED Pilot Light. Please read all instructions carefully before beginning installation or use. Retain this manual for future reference.

2. Likarolo tsa lihlahisoa

  • Heavy Duty "Triple Wire" Contacts: Ensures secure and reliable electrical connections.
  • Thick-Walled, Impact-Resistant Thermoplastic Nylon Cover and Body: Designed for durability and to withstand abuse in various environments.
  • Patented Lockout Feature: Prevents the GFCI from resetting if it is not functioning properly or is miswired due to reversal of line and load leads, enhancing safety.
  • Triple-Drive Combination Terminal Screws: Facilitates easier and more versatile wiring connections.
  • High-Visibility LED Pilot Light: Clearly indicates when the circuit is live and the GFCI is providing protection.

3. Boitsebiso ba Tšireletseho

WARNING: TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER OR FUSE BOX AND TEST THAT POWER IS OFF BEFORE WIRING!

  • Ho kenya ho lokela ho etsoa ke setsebi sa motlakase se tšoanelehang ho latela melao eohle ea motlakase ea naha le ea lehae.
  • Do not install in wet locations unless specifically rated for such use.
  • Netefatsa motheo o nepahetseng.
  • Always test the GFCI outlet monthly to ensure proper operation.
  • This device is designed to protect against ground faults, not against electrical shock from contact with both circuit conductors (hot/neutral) or from short circuits.

4. Seta (Instalment)

Before installation, ensure the power to the circuit is OFF at the service panel. Use a voltage tester to confirm the circuit is de-energized.

Litaelo tsa Wiring

The Leviton 7591-PLG GFCI outlet has LINE and LOAD terminals. It is crucial to connect the incoming power (LINE) to the correct terminals and the outgoing power (LOAD) to the appropriate terminals if protecting downstream outlets.

Leviton 7591-PLG Smart Lock GFCI Single Outlet, Gray

Image: Leviton 7591-PLG Smart Lock GFCI Single Outlet in Gray. This image shows the front view of the GFCI outlet, highlighting its single receptacle and the test/reset buttons.

  1. Lokisa Lithapo: Strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the circuit wires.
  2. Khetholla Lithapo: Identify the LINE (incoming power from breaker) and LOAD (outgoing power to other outlets) wires. Also identify the hot (black), neutral (white), and ground (green/bare copper) wires.
  3. Hokela Ground Wire: Connect the bare copper or green insulated ground wire from the circuit box to the green ground screw on the GFCI outlet.
  4. Connect LINE Wires: Connect the incoming hot (black) LINE wire to the brass LINE terminal screw and the incoming neutral (white) LINE wire to the silver LINE terminal screw.
  5. Connect LOAD Wires (Optional): If protecting downstream outlets, connect the outgoing hot (black) LOAD wire to the brass LOAD terminal screw and the outgoing neutral (white) LOAD wire to the silver LOAD terminal screw. If not protecting downstream outlets, cap the LOAD wires individually.
  6. Secure Outlet: Carefully fold wires into the wall box and secure the GFCI outlet with mounting screws.
  7. Kenya Wallplate: Hokela letlapa la lebota.
  8. Khutlisa Matla: Turn power ON at the circuit breaker.

5. Litaelo tsa Ts'ebetso

Matla a Phahamiso ea Pele

After installation and restoring power, the GFCI outlet should be in a tripped state (RESET button will be out). Press the RESET button firmly to restore power to the outlet. The LED pilot light will illuminate, indicating the GFCI is functioning and providing protection.

Testing the GFCI

It is recommended to test the GFCI monthly to ensure proper operation.

  1. Plug alamp or other device into the GFCI outlet and turn it ON.
  2. Press the TEST button on the GFCI. The device should trip, and the lamp/device should turn OFF. The RESET button should pop out.
  3. Press the RESET button firmly. The lamp/device should turn ON.
  4. If the GFCI fails to trip or reset, it may be faulty or improperly wired. Discontinue use and consult a qualified electrician.

Resetting the GFCI

If the GFCI trips (RESET button pops out), it indicates a ground fault has occurred. To restore power, unplug any devices from the outlet, then press the RESET button firmly. If the GFCI immediately trips again, there may still be a ground fault or a wiring issue. Investigate the cause before attempting to reset again.

6. Tlhokomelo

The Leviton 7591-PLG GFCI outlet requires minimal maintenance. The primary maintenance task is the monthly testing procedure described in the Operating Instructions section. Keep the outlet and surrounding area clean and free from debris. Do not use abrasive cleaners or solvents.

7. Ho rarolla mathata

BothataLebaka le ka khonehangTharollo
GFCI e ke ke ea qala bocha.No power to the GFCI; GFCI is miswired (LINE/LOAD reversed); Internal fault; Downstream ground fault.Check circuit breaker. Verify LINE/LOAD wiring. If miswired, correct immediately. Unplug all devices from the GFCI and any downstream outlets, then try to reset. If it still won't reset, replace the GFCI.
Maeto a GFCI khafetsa.Ground fault in connected appliance; Ground fault in downstream wiring/outlets; Moisture in circuit.Unplug appliances one by one to identify the faulty device. Inspect wiring for damage or moisture. If the problem persists, consult an electrician.
No power from GFCI, but RESET button is in.No power to the GFCI; Internal fault.Check circuit breaker. Test the GFCI (press TEST, then RESET). If it doesn't respond, the GFCI may be faulty and needs replacement.
LED Pilot Light is off.GFCI is tripped; No power to the GFCI; LED malfunction.Press RESET. Check circuit breaker. If the GFCI functions but the LED remains off, the LED may be faulty, but the GFCI protection should still be active.

8. Litlhaloso

TlhalosoLintlha
BrandLeviton
Mohlala7591-PLG
Ampkhalefo15 Amps
MoqtageLi-volts tse 125
Kakaretso ea Matla a Matla1
MmalaHlooho
Lintho tse bonahalangNylon (Thermoplastic)
Mofuta oa SehokeloHokela
Mofuta oa Plug ea MatlaMofuta oa A - 2 phini (Amerika Leboa)
Lisebelisoa tse lumellanangTsohle
UPC078477409992
ASINB003CYKABU

9. Boitsebiso ba Tiisetso

Sehlahisoa sena sa Leviton se koahetsoe ke Tiisetso e Lekanyelitsoeng ea Selemo se 2. For specific terms and conditions, please refer to the official Leviton warranty documentation or contact Leviton customer support. This warranty typically covers defects in materials and workmanship under normal use and service.

10. Tšehetso

Bakeng sa thuso ea botekgeniki, ho rarolla mathata, kapa likopo tsa waranti, ka kopo ikopanye le tšehetso ea bareki ba Leviton:

  • Websebaka: Etela Leviton ea semmuso website for FAQs, product documentation, and support resources.
  • Mohala: Sheba karolo ea ho ikopanya le Leviton websebaka sa marang-rang bakeng sa linomoro tsa mohala tsa tšebeletso ea bareki.
  • Lisebelisoa tsa Marang-rang: Visit the Leviton Store on Amazon

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.